Operator's Manual
First Edition • Third Printing
Operating Instructions
52
SX
™
-105 XC
™
• SX
™
-125 XC
™
Part No. 1270327GT
Platform Out of Level (P22 code)
Bypass key position to be used to level the
platform if ground control display shows platform
out of level (P22) and platform level controls do
not work.
To operate:
1
Turn the engine off.
2
Turn the main key switch to ground control.
Remove the key from the main key switch and
insert the key into the bypass/recovery key
switch.
3
Turn the bypass/recovery
key switch to the bypass
position.
4
Using auxiliary power, operate the platform
level button to level the platform.
5
Turn the bypass/recovery key switch to the run
position.
6
Remove the key from the bypass/recovery key
switch and insert the key into the main key
switch.
7
Push in and then pull out the red Emergency
Stop button.
8
If the P22 code is still visible, tag and remove
the machine from service until the fault has
been corrected by a qualified service
technician.
Содержание Genie SX-105 XC
Страница 11: ...First Edition Third Printing Operator s Manual General Safety Part No 1270327GT SX 105 XC SX 125 XC 9 ...
Страница 27: ...First Edition Third Printing Operator s Manual Controls Part No 1270327GT SX 105 XC SX 125 XC 25 ...
Страница 46: ...Operator s Manual First Edition Third Printing Inspections 44 SX 105 XC SX 125 XC Part No 1270327GT ...
Страница 76: ......