Operator's Manual
First Edi
tion • Third Printing
Inspections
36
SX
™
-105 XC
™
• SX
™
-125 XC
™
Part No. 1270327GT
At the Platform Controls
Test Emergency Stop
31
Turn the key switch to platform control.
32
Push in the platform red Emergency Stop
button to the off position.
Result: The engine should shut off and no
functions should operate.
33
Pull out the red Emergency Stop button and
restart the engine.
Test the Horn
34
Press the horn button.
Result: The horn should sound.
Test the Tilt Sensor Alarm
35
Move a toggle switch, such as the engine idle
select switch.
Result: The alarm should sound at the
platform controls.
Test the Foot Switch
36
Push in the platform red Emergency Stop
button to the off position.
37
Pull out the red Emergency Stop button to the
on position and do not start the engine.
38
Press down the foot switch and attempt to
start the engine.
Result: The engine should not start.
39
Do not press down the foot switch and restart
the engine.
Result: The engine should start.
40
Do not press down the foot switch and test
each machine function.
Result: No functions should operate.
Test Machine Functions
41
Press down the foot switch.
42
Activate each machine function control handle
or toggle switch.
Result: All boom and platform functions should
operate through a full cycle.
Содержание Genie SX-105 XC
Страница 11: ...First Edition Third Printing Operator s Manual General Safety Part No 1270327GT SX 105 XC SX 125 XC 9 ...
Страница 27: ...First Edition Third Printing Operator s Manual Controls Part No 1270327GT SX 105 XC SX 125 XC 25 ...
Страница 46: ...Operator s Manual First Edition Third Printing Inspections 44 SX 105 XC SX 125 XC Part No 1270327GT ...