OPERATION
16
Boss 2000E (08–03)
DRAINING CLEAN WATER TANK
To drain leftover clean water, place extractor over a
drain sink or floor drain, pull clear gallon marker tube
off hose barb and drain (Figure 31).
FIG. 31
RINSING RECOVERY TANK
Rinse recovery tank after each use. This will prevent a
foul odor later.
1.
Remove recovery tank dome.
2.
Flush out inside of recovery tank with clean water.
3.
Drain recovery tank.
CIRCUIT BREAKERS
The drive and brush motors are protected by resetable
circuit breakers. They are designed to stop current
flow when circuit overload occurs. Once a circuit
breaker has tripped, determine problem, let motor cool
down and manually press reset button. Circuit
breakers are located at rear of control console. The
vacuum motor is thermally protected and will
automatically shut–off when an overload occurs
(Figure 32).
FIG. 32
MACHINE MAINTENANCE
To keep machine in good working condition, simply
follow machines daily, weekly and monthly
maintenance procedures.
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, unplug
cord from wall outlet and remove key.
ATTENTION: Contact an Authorized Service Center
for machine repairs. Machine repairs performed by
other than an authorized person will void your
warranty.
Your machine is equipped with an hour meter located
on the back of the control console. This meter keeps a
running hour total of operation. Use this meter to
determine when machine should be maintained and
also to log machine hours when service was
performed.
To Access Internal Components:
The machine is designed to hinge open to allow easy
machine repair.
1.
Turn key off, unplug power cord and drain
recovery tank.
2.
Remove vacuum hose from recovery dome and
prespray wand from holder.
3.
Disconnect drain hose from holder.
4.
Carefully hinge open recovery tank to the left
(Figure 33).
FIG. 33
To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com