OPERATION
14
Boss 2000E (08–03)
OPTIONAL FLOOR TOOL SETUP AND
OPERATION
(See Available Optional Accessories in OPTIONS
section)
Machine is equipped with accessory connections to
use attachments such as an optional floor tool. Floor
tool enables you to reach areas that the machine is
unable to, such as alcoves and corners. Cleaning with
floor tool requires prespraying carpet, using built–in
prespray wand, before operating tool.
WARNING: Do Not Use Flammable Liquids Or
Operate Machine In Or Near Flammable Liquids,
Vapors Or Combustible Dusts.
WARNING: Do Not Pick Up Flammable
Materials Or Reactive Metals.
NOTE: Vacuum area before cleaning.
1.
With key turned off, disconnect internal vacuum
hose from recovery dome and replace with
extension vacuum hose (Figure 24).
FIG. 24
2. Connect floor tool to vacuum hose.
3.
Connect solution hose to accessory tool coupler at
top of machine (Figure 25).
FIG. 25
4.
Connect solution hose to floor tool.
5.
Raise brush.
6.
Before cleaning with floor tool you must prespray
carpet first, using the prespray wand.
7. Connect prespray wand to 2–25’ solution hoses
and connect solution hose to quick coupler located
at rear of machine (Figure 26).
FIG. 26
8.
Turn key on.
9.
Press the two Light/Deep Clean switches to
”LIGHT CLEAN” for PRESPRAY mode (Blue Area)
(Figure 27).
FIG. 27
NOTE: Cleaning mode lamp will not light in the
prespray mode, this is normal.
10. Turn on ”PUMP” switch.
11. Take prespray wand and spray area to be cleaned.
To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com