CAN 1 Baud Rate (ID=147)
Parameter defines CAN 1 bus baud rate. For Auto Baud rate value is 0. Available baud rates
are 50, 100, 125, 250, 500 and 1000 kbps.
Table 12 CAN 1 Baud Rate
Minimum
value
Maximum
value
Recommended
value
Value type
0
1000
250
U32
CAN 1 operational mode (ID=148)
Parameter defines if CAN 1 line working at silent mode or normal mode. 0 – Silent,
1 – Normal
Table 13 CAN Baud Rate
Minimum
value
Maximum
value
Recommended
value
Value type
0
1
0
U8
CAN 2 Enable parameter (Used for tachograph) (ID=149)
Parameter enables or disables CAN 2 interface. Possible values: 0 – disable, 1 – enable as
Tacho line, 2 – enable as FMS line.
Table 14 CAN 2 Enable parameter
Minimum
value
Maximum
value
Recommended
value
Value type
0
2
1
U8
CAN 2 Baud Rate (ID=150)
Parameter defines CAN 2 bus baud rate. Available baud rates are 250, 500.
Table 15 CAN Baud Rate
Minimum
value
Maximum
value
Recommended
value
Value type
250
500
250
U32
ManualCAN CAN#0 I/O
properties
(ID=x406):
CAN#0 I/O parameter priority
Parameter defines CAN I/O element priority. Enable or Disable.
Table 16 CAN#0 I/O priority
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value type
0
2
0
CAN#0 I/O CAN Type ID
U8