128
Category – shows CAN message;
Parameter – shows configurable parameter name;
Value – shows scanned value of parameter;
Send data to server – allows to choose the type of data when it‘s generated:
o
Disabled – Data will not be collected
o
On low priority – records will be generated as low priority events;
o
On high priority – records will be generated as high priority events and immediately
sent to server via GPRS (if GPRS is available);
o
On panic - records will be generated as panic priority events and immediately sent
to server via GPRS, if GPRS is not available records will be sent via SMS messages;
Data acquisition type – allows to choose when records are generated:
o
Monitoring – monitors data;
o
On change – record is generated when parameter value is changed;
o
Hysteresis – record is generated when increasing parameter value becomes higher
than High value, and decreasing becomes less than Low value
o
Event on exit – record is generated when parameter value becomes higher than
High value or lower than Low value;
o
Event on entrance – record is generated when parameter value becomes between
High and Low values;
o
Event on both – record is generated when parameter value crosses High or Low
values;
Low – allows to choose low value for Data acquisition;
High – allows to choose High level for Data acquisition;
Figure 103 CAN data table