Figure 71 Immobilizer configuration parameters
Immobilizer.
Selects which DOUT will control Immobilizer Scenario.
IButton list checking
. When
disabled turn on Immobilizer Scenario.
Ignition timeout.
Time that need to be passed when ignition (DIN1) turns off to reactivate
scenario.
Authorized Driving (iButton list checking enabled).
Gives ability to use vehicle for 500
specific iButton owners (specified in iButton list). Selected DOUT is controlled by scenario for
user needs, to manage buzzer, LED etc.
13.3.2
Configuration
Figure 72 Authorized driving configuration parameters
Immobilizer.
Selects which DOUT will control Immobilizer Scenario.
iButton list checking.
When
enabled turn on authorized driving Scenario.
Ignition timeout.
Time that need to be passed when ignition (DIN1) turns off to reactivate
scenario.
13.4
Excessive Idling Scenario
Scenario is activated when vehicle stops for specific amount of time. You can configure
time it takes to turn on this scenario (Time to Stationary). Scenario is activated until vehicle starts
moving and keeps moving for amount of time that is configured (time to movement).