GS2101M IP2WiFi Adapter Command Reference Guide
1VV0301499
Rev. 2.0
83
2019-08-05
5.1.4 Sync Loss Interval
This command is used to set the GS node for sync loss interval for n times the beacon
interval so that if the GS node does not receive the beacon for this time, it informs the user
this event is “Disassociation event.”
Command Syntax
AT+WSYNCINTRL=<n>
Parameter Description
describes the Sync Loss Interval parameters.
Synchronous Response
describes the synchronous responses and remarks for the Sync Loss
Interval command.
Asynchronous Response
describes the asynchronous responses and remarks for the Sync Loss
Interval command.
Table 53 Sync Loss Interval Parameters
Parameter
Optional/Mandatory
Value
Description
n
Mandatory
Value range:
1-63325
Default
value:
100
This parameter specifies the beacon count. Time
difference between two beacons are approximately
100msec.
Example: If n=30 and 30 consecutive beacons are
missed then, SYNC loss is detected and GS node sends
the Disassociation packet to the Access Point.
The time taken for detecting sync loss for n=30 is
approximately 3seconds (30*100msec).
Table 54 Sync Loss Interval Synchronous Responses
Responses
Remarks
OK
Success
ERROR:INVALID INPUT
Invalid parameter (out of range)