GS2101M IP2WiFi Adapter Command Reference Guide
1VV0301499
Rev. 2.0
145
2019-08-05
6.2.2 Battery Warning/Standby Level Set
This command is used to set the battery warning/standby level to and enable the GS node’s
internal battery level monitoring logic starts. This command should be executed before the
battery check start command (see
6.2.1 Battery Check Start, page 144
Command Syntax
AT+BATTLVLSET=<Warning Level>,<Warning
Frequency>,<Standby Level>
Parameter Description
describes the Battery Warning/Standby Level Set parameters.
Synchronous Response
describes the synchronous responses and remarks for Battery
Warning/Standby Level Set command.
Table 124 Battery Warning/Standby Level Set Parameters
Parameter
Optional/Mandatory
Value
Description
Warning Level
Mandatory
N/A
The battery voltage, in millivolts.
When the GS node batter voltage is
less than this level, it sends a message
“Battery Low” to the serial interface.
Warning Frequency
Mandatory
N/A
This is the frequency at which the GS
node sends the “Battery Low”
message to the serial interface once
the GS node’s battery check detected
low battery.
Standby Level
Mandatory
N/A
The battery voltage, in millivolts.
When the GS node battery voltage
reaches this level, it sends the
message “Battery Dead” to the serial
interface and goes into a long Standby
mode.
Table 125 Battery Warning/Standby Level Set Synchronous Responses
Responses
Remarks
OK
Success
ERROR:INVALID INPUT
If parameters are not valid.