GS2101M IP2WiFi Adapter Command Reference Guide
1VV0301499
Rev. 2.0 177
2019-08-05
Parameter Description
describes the Live Calibration parameters.
Synchronous Response
describes the synchronous responses and remarks for the Live
calibration command.
Example
AT+WLCALEN=1
OK
Table 153 Live Calibration Parameters
Parameter Optional/Mandatory
Value
Description
value
Mandatory
0, 1, ?
Default value - 1
0:Disables live calibration.
1:Enables live calibration.
?:Provides the current value of the live
calibration flag. Returns value 1 when live
calibration is enabled or return 0 when live
calibration is disabled.
Table 154 Live Calibration Synchronous Responses
Responses
Remarks
OK
Success
ERROR:INVALID INPUT
If parameters are not valid
(If value is other than 0, 1, or ? )
NOTE:
This command needs to be used with caution only during assembly and
manufacturing. The following steps need to be performed during assembly (if
required):
1.) Erase live calibration data.
2.) Once the system boots up, disable live calibration, as it is automatically
enabled when the system boots up.
3.) Live calibration is scheduled to start in the next boot based on the following
triggers:
- During scan
- In associated state
- Unsolicited Tx and unsolicited Rx
- RF commands or RF stop command
- Going to standby