S12 - Escape Prompt Delay
ATS12=[<time>]
Set command sets:
1)
the minimum period, before receipt of the first character of the three escape
character sequence, during which no other character has to be detected in
order to accept it as valid first character;
2)
the maximum period allowed between receipt of first or second character of
the three escape character sequence and receipt of the next;
3)
the minimum period, after receipt of the last character of the three-escape
character sequence, during which no other character has to be detected in
order to accept the escape sequence as a valid one.
Parameter:
<time>
- expressed in fiftieth of a second
20..255 - factory default value is 50.
Note: the minimum period
S12
has to pass after
CONNECT
result code
too, before a received character is accepted as valid first character of the
three escape character sequence.
ATS12?
Read command returns the current value of
S12 parameter
.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
S25 -Delay To DTR Off
ATS25=[<time>]
Set command defines the amount of time, in hundredths of second, that the device
will ignore the
DTR
for taking the action specified by command
&D
.
Parameter:
<time>
- expressed in hundredths of a second
0..255 - factory default value is 5.
Note: the delay is effective only if its value is greater than 5.
ATS25?
Read command returns the current value of
S25 parameter
.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s
S30 -Disconnect Inactivity Timer
ATS30=[<tout>]
Execution command has no effect and is included only for backward compatibility
with landline modems.
ATS30?
Read command returns the current value of
S30 parameter
.
Note: the format of the numbers in output is always 3 digits, left-filled with 0s