DE910-DUAL AT commands reference guide
80392ST10102A Rev.2 – 2012-07-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 136 of 261
3.5.6.1.35.
#CFLO – Command Mode Flow Control
AT#CFLO=
<mode>
Set command enables/disables the flow control in command mode. If enabled,
current flow control is applied to both command mode and data mode.
Parameter:
<mode>
0 – Disable flow control set in command mode (factory default)
1- Enable flow control set in command mode
Note: This behaviour is valid only for Main UART port.
AT#CFLO?
Read command reports current setting value , in the format:
#CFLO: <mode>
AT#CFLO=?
Test command reports the range of supported values for parameter
<mode>
3.5.6.1.36.
#MONI - Cell Monitor
AT#MONI[=
[<number>]]
Set command to select one of three pilot set, Active/Candidate/
Neighbor set, from which extract CDMA-related information.
Parameter:
<number>
<CDMA network>
0 – it is the active set (factory default)
1 – it is the candidate set
2 – it is the neighbor set
3..7 – it is not available
Note: Candidate set (number = 1) display in traffic state only. That is CDMA
specifications (refer to 2.6.6.1.2 Pilot Sets of C.S0005). If mobile stay in Idle state,
pilot set and strength are displayed to 0.
a)
When number is set to 0 (active set), extracting information format is:
#MONI: A_PN:<PNn>,A_PN_STR:<PNn_str>
b)
When number is set to 1 (candidate set), extracting information format is:
#MONI: C_PN:<PNn>,C_PN_STR:<PNn_str>
c)
When number is set to 2 (neighbor set), extracting information format is:
#MONI: N_PN:<PNn>,N_PN_STR:<PNn_str>
Содержание DE910-DUAL
Страница 1: ...80392ST10102A Rev 2 2012 07 03...