DE910-DUAL AT commands reference guide
80392ST10102A Rev.2 – 2012-07-03
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 229 of 261
#TESTORI – Test Origination
AT#TESTORI=
<svc_opt>[,<num>]
Set command originates a(loopback) test call according to
<idx >
parameter.
Parameter:
< svc_opt >
Service option for test call:
–
Rate Set 1 Loopback Service Option(Serivce Option: 0x02)
–
Rate Set 2 Loopback Service Option(Serivce Option: 0x09)
–
Loopback service Option 55(Serivce Option: 0x37)
–
Markov Service Option(Serivce Option: 0x8002)
–
Markov Service Option (13K) (Serivce Option: 0x801C)
–
Rate Set 2 Markov Service Option(Serivce Option: 0x801F)
–
Rate Set 1 Markov Service Option(Serivce Option: 0x801E)
–
Markov Service Option 54(Serivce Option: 0x36)
–
Service option for Simple TDSO(Serivce Option: 0x8008)
–
Service option for FULL TDSO(Serivce Option: 0x20)
< num >
Destination number for test calls
Example
AT#TESTORI=0
OK
AT#TESTORI=0 ,12345678
OK
#CRXD – RX Diversity for CDMA
AT#CRXD=<1x
rxd>,<evdo rxd>
Set command enables/disables RX Diversity for CDMA.
Parameter:
<1x rxd>
- RX Diversity enable/disable for 1x
0 – disable(default)
1 - enable
<evdo rxd>
- RX Diversity enable/disable for evdo
0 – disable(default)
1 - enable
Note: This command saved in NVM.
Note: This action works after power cycle.
Содержание DE910-DUAL
Страница 1: ...80392ST10102A Rev 2 2012 07 03...