#PSET - Audio Profile Setting
#PSET:<scal_in>,<scal_out>,<side_tone_atten>,<adaption_speed>,
<filter_length>,<rxtxrelation>,<nr_atten>,<nr_w_0>,<nr_w_1>,
<add_atten>,<min_atten>,<max_atten>
It is not allowed if active audio profile is 0.
AT#PSET=?
Test command returns the supported range of values for the audio
parameters.
#SHFAGC - Handsfree Automatic Gain Control
AT# SHFAGC =
<mode>
It has no effect and is included only for backward compatibility.
Parameter:
<mode>
(0,1) - (0 is default)
Note: This parameter is saved in NVM issuing AT&W command.
AT# SHFAGC?
Read command reports the value of parameter <mode>, in the format:
#SHFAGC: <mode>
AT# SHFAGC =?
Test command returns the supported range of values of parameter
<mode>
.
# SHFNR - Handsfree Noise Reduction
AT#SHFNR =
<mode>
It has no effect and is included only for backward compatibility.
Parameter:
<mode>
(0,1) - (0 is default)
Note: This parameter is saved in NVM issuing AT&W command.
AT#SHFNR?
Read command reports the value of parameter <mode>
, in the format:
#SHFNR: <mode>
AT#SHFNR =?
Test command returns the supported range of values of parameter
<mode>
.
Содержание DE910-DUAL