Telex Communications
87
GPI In
General Purpose Inputs and Outputs (GPIO or GPI) controls devices that use switch contact closures, DC
voltages, or similar methods. GPI Inputs can be used to activate key assignments. For example, a lighting system
can be controlled from keypanel keys or key a transmitter during transmission. GPI Inputs can also be used as inputs
to UPL statements. For example, you could program a console switch to load an entirely new intercom system setup
file.
ADAM and ADAM CS intercom systems have a General Purpose Interface (GPI) port. GPI ports have eight control
outputs (also referred to as relays) and eight control inputs. The location of the GPI port on the ADAM and ADAM CS
is as follows:
ADAM:
Located on XCP-ADAM-MC Master Controller Breakout Panel, J11.
ADAM CS: Located on ADAM CS back panel, J903.
GPI Port Pin-out
All 25-pin GPI Port connectors have the same pin-out as follows:
Pin No. Function
Pin No. Function
1
GPI In #1 (+5 to +18 VDC)
2
GPI In #2 (+5 to +18 VDC)
3
GPI In #3 (+5 to +18 VDC)
4
GPI In #4 (+5 to +18 VDC)
5
GPI In #5 (+5 to +18 VDC)
6
GPI In #6 (+5 to +18 VDC)
7
GPI In #7 (+5 to +18 VDC)
8
GPI In #8 (+5 to +18 VDC)
9
Common
10
Common
11
Common
12
Common
13
Common
14
GPI Out #1
15
GPI Out #2
16
GPI Out #3
17
GPI Out #4
18
GPI Out #5
19
GPI Out #6
20
GPI Out #7
21
GPI Out #8
22
Common
23
Common
24
Common
25
Common
Содержание Azedit
Страница 1: ...1 9350 7532 000 Rev A October 30 2003 ...
Страница 2: ...2 ...
Страница 3: ...3 ...
Страница 4: ...4 This Page left Intentionally Blank ...
Страница 15: ...Telex Communications 15 ScreenDescriptions ...
Страница 133: ...Telex Communications 133 ...
Страница 134: ...Telex Communications 134 Appendix A AZedit Keyboard Shortcuts ...
Страница 138: ...Telex Communications 138 ...
Страница 139: ...Telex Communications 139 Appendix B AZedit Quick Start ...
Страница 143: ...Telex Communications 143 ...
Страница 177: ...Telex Communications 177 W Warn on Exit A Warn on Exit message appears to confirm whenever you attempt to exit AZedit ...