Telex Communications
131
Download Firmware Updates
Updating Master Controller Firmwaree
Warning!
The following procedure will cause one or more brief disruptions in intercom communications. Also, save
your intercom system configuration before proceeding.
From the File menu, select Save.
Later, if you need to restore the intercom configuration from disk, use Send File in the Online menu.
Master Controller Update: ADAM CS, ADAM Single Frame, ADAM DBX System, Zeus, Zeus II
Before you begin, be sure to verify that SERVER mode has been disabled. Also, it is very important to take the
Standby Controller card out of the frame, if one is installed.
Note: The Active Master Controller will have a red LED ON in the status LED window.
To update the master controller, do the following:
1. From the Status Menu, select Software Versions.
A popup list appears.
2. From the Software Versions popup list, select Master Controllers.
The Master Controller Version Information screen appears.
3. Right-click the active Master Controller, and then select Download Firmware.
The Firmware Download screen appears.
Note
: You can also press Ctrl+Shift+D to open the Download Firmware screen once the Master
Controller is highlighted.
4. From the Download Firmware screen, select the firmware update file.
5. Click Open.
The firmware update appears in the Download Firmware screen.
6. Click Begin Download.
This process can take from one to five minutes depending on the baud rate you have selected.
Note
: If there is any disruption in the communications link during the download, you will get an error
message. In this case, repeat the download.
7. When the file has been completely downloaded, the master controller will begin processing the
update.
IMPORTANT: Any disruption at this point, such as a loss of power, removing or resetting cards
(ADAM, ADAM CS, etc.) will result in Master Controller failure!
If this happens, you will either have to return the affected unit for replacement or you will have to
remove the EEPROM chip(s) from the affected unit and manually reprogram them with an
EEPROM programming tool.
ADAM and ADAM CS users do NOT proceed with the update of any more cards until you
identify the problem.
The AZedit session goes offline for 15-20 seconds when the card performs a reset. It automatically
will reconnect when it is finished.
M
Содержание Azedit
Страница 1: ...1 9350 7532 000 Rev A October 30 2003 ...
Страница 2: ...2 ...
Страница 3: ...3 ...
Страница 4: ...4 This Page left Intentionally Blank ...
Страница 15: ...Telex Communications 15 ScreenDescriptions ...
Страница 133: ...Telex Communications 133 ...
Страница 134: ...Telex Communications 134 Appendix A AZedit Keyboard Shortcuts ...
Страница 138: ...Telex Communications 138 ...
Страница 139: ...Telex Communications 139 Appendix B AZedit Quick Start ...
Страница 143: ...Telex Communications 143 ...
Страница 177: ...Telex Communications 177 W Warn on Exit A Warn on Exit message appears to confirm whenever you attempt to exit AZedit ...