Model 300E Carbon Monoxide Analyzer
Instruction Manual
Operating Instructions
P/N 04288 REV: A
99
Text strings are used to identify iDAS data channels and parameters as well as
Setup Variables These types of variables often include numbers or spaces within
their names that make them easy for the user to understand, but difficult for the
instrument to recognize unless they’re enclosed in quotes.
Variable, Message, and Other Names
Some commands allow you to access variables, messages, and other items, such as
A2
data channels, by name. When using these commands you must type the entire
name of the item; you cannot abbreviate the names.
6.9.4.
Asynchronous Status Reporting
Asynchronous reporting of status messages as an audit trail is one of the two
principal uses for the RS-232 interface (the other is the command line interface for
controlling the instrument). You can effectively disable the asynchronous reporting
feature by setting the interface to quiet mode, see Section 6.8.4.
Asynchronous reports include
A2
reports, warning messages, calibration and
diagnostic status messages. Refer to Appendix A for a list of the messages, and
Section 6.9.2 for information on controlling the instrument via the RS-232
interface.
6.9.4.1. General Message Format
All messages output from the instrument (including those output in response to a
command line request) have the format:
X DDD:HH:MM [Id] MESSAGE<CRLF>
WHERE:
X
à
Command Type Designator: A single character indicating the message type.
DDD:HH:MM
à
TIME STAMP: The The Date and Tim the message was issued. The
Day-of-year (DDD) as a number from 1 to 366, the hour of the day (HH) as a
number from 00 to 23, and the minute (MM) as a number from 00 to 59.
[ID]
à
MULTIDROP ADDRESS DESIGNATOR: The 4-digit Multidrop instrument ID
number.
MESSAGE
à
MESSAGE CONTENT: May contain warning messages, test
measurements,
A2
reports, variable values, etc.
Содержание 300E
Страница 40: ...Getting Started Model 300E Carbon Monoxide Analyzer Instruction Manual 40 P N 04288 REV A INTENTIONALLY BLANK ...
Страница 122: ...Operating Instructions Model 300E Carbon Monoxide Analyzer Instruction Manual 122 P N 04288 REV A INTENTIONALLY BLANK ...
Страница 186: ...THEORY OF OPERATION Model 300E Carbon Monoxide Analyzer Instruction Manual 186 P N 04288 Rev A INTENTIONALLY BLANK ...
Страница 224: ...Model 300E Carbon Monoxide Analyzer Instruction Manual Appendix A P N 04288 REV A INTENTIONALLY BLANK ...
Страница 226: ...Model 300E Carbon Monoxide Analyzer Instruction Manual Appendix B P N 04288 REV A INTENTIONALLY BLANK ...
Страница 228: ...Model 300E Carbon Monoxide Analyzer Instruction Manual Appendix C P N 04288 REV A INTENTIONALLY BLANK ...
Страница 230: ...Model 300E Carbon Monoxide Analyzer Instruction Manual Appendix D P N 04288 REV A INTENTIONALLY BLANK ...
Страница 236: ......
Страница 252: ......