GPS7 GPS Synchronization and Timecode Module
Information about the Oven Calibration menu is available in the
CAL OVEN
Submenu
section. (See page 2-28.)
NOTE.
Perform the mainframe internal frequency calibration at least once a year
to compensate for oscillator drift. With software version 5.1 or greater and a
GPS7 module installed, this calibration can be done while the instrument is in
service.
WARNING.
Dangerous electric shock hazards exist inside the TG700 mainframe.
Only quali
fi
ed service personnel should perform these procedures. Failure to use
appropriate precautions can result in injury or death.
Internal frequency calibration.
Perform the following procedure to set the internal
frequency of the mainframe internal oscillator. This adjustment stores the current
frequency of the oscillator while it is locked to a GPS signal. It is stored for used
when the instrument is set to
Internal
mode. This procedure can be done without
any disruption to operation and is best performed in the operating environment
of the instrument.
1.
Connect the power cord to the TG700 mainframe.
2.
Check for error messages as the instrument starts.
3.
Connect a GPS signal to the rear of the module.
4.
Allow the instrument to warm up for a minimum of 20 minutes.
5.
Press the
MODULE
button until
GPS7 : STATUS
appears.
6.
Check that the signal status shows
Locked
.
7.
Check that signal lock indicator displays
Fine
:
a.
Press the up (
▲
) arrow button to select
DIAGNOSTICS
.
b.
Press the
ENTER
button.
c.
Press the right (
►
) arrow button to select
TUNE
.
d.
Check that
Fine
is showing on the right side of the LCD display.
8.
Press the
MODULE
button until
TG700
appears.
9.
Press the up (
▲
) arrow button to select
UTILITY
.
10.
Press the
ENTER
button.
11.
Press the up (
▲
) arrow button to select
CAL OVEN : SELECT
.
12.
Press the
ENTER
button to access the
Internal Frequency Calibration
submenu.
TG700 TV Signal Generator Platform User Manual
3–99
Содержание TG700
Страница 1: ...xx TG700 TV Signal Generator Platform ZZZ User Manual P071197003 071 1970 03...
Страница 2: ......
Страница 27: ...Getting Started...
Страница 28: ......
Страница 34: ...Getting Started Figure 1 1 Installing the rackmount hardware 1 6 TG700 TV Signal Generator Platform User Manual...
Страница 67: ...Operating Basics...
Страница 68: ......
Страница 111: ...Modules...
Страница 112: ......
Страница 337: ...Index...
Страница 338: ......