Operating
lnstructions-5110
Horizontal
P
l
ug-ln Compartment.
Alternate
or
Chopped
display switching is selected
on a time-base unit
operated
in the horizontal compartment. When the
Display switch
is
out (Alt), a
negative impulse is supplied
at
the end of the sweep
to allow alternate switching
between
plug-ins and plug-in channels. When the Display
switch
is pushed in
(Chop),
a chopped display will appear
if
a
multi-trace display is
required by the plug-ins in the
vertical compartments. A vertical plug-in
unit
operated in
the
horizontal
compartment has a
permanent internal
connection to provide a chopped display if it is required.
Dual-Sweep
Displays.
When
a dual-sweep
time-base
unit
is operated in
the
horizontal compartment, the
alternate
and chopped time-shared switching for either
the
A or B
sweep is identical to that
for a single time-base
unit.
However, if both the A and B sweeps are operating,
the
oscilloscope operates in the independent pairs
mode.
Under
this condition, the
left vertical unit is always
displayed at
the sweep rate
of the A time base and the right
vertical unit is displayed at the
sweep
rate of the B time
base.
This
results in two displays that have completely
independent
vertical deflection and chopped or
alternate
sweep switching.
Switching
Sequence.
Four
display time slots are
provided
on a time-sharing basis. When two vertical plug
ins
are active,
each receives two time slots, so the
switching
sequence is: left,
left, center, center, etc. The
two time slots allotted
to each
plug-in are divided between
amplifier channels
in
a dual-trace unit; if two dual-trace
plug-ins
are
active, then the switching sequence is:
left
Channel
1, left
Channel 2,
center Channel 1, center
Channel 2,
etc.
If
only one vertical plug-in is active, it
receives
all four
time slots. The switching sequence is the
same
for both the Alternate and Chopped display modes.
Vertical
Display
Mode
Display
On.
To
display a
signal, the Display button of
the applicable
vertical
plug-in unit must be pushed in to
activate the unit. If two plug-ins are installed in
the vertical
compartments
and
only
the signal from one of the units is
wanted,
set
the Display switch
of
the unwanted unit to Off
(button
out). If neither
plug-in is activated, the signal from
the left
unit is
displayed. Both plug-inscan be activated for
multi-trace
displays.
Alternate
Mode.
The alternate
position of
the time-base
unit
Display
switch produces a display that alternates
between
activated plug-ins and amplifier channels
with
each
sweep of the
crt. The switching sequence is describ
ed under Display Switching Logic in this section.
Although
the Alternate
mode can be used at all sweep
rates, the
Chop mode provides a more satisfactory display
at
sweep
rates from about one millisecond/division to five
seconds/division. At these slower sweep rates, alternate
mode switching
becomes difficult to view.
BASIC
OSCILLOSCOPE
APPLICATIONS
The oscilloscope
and its
associated plug-in units
provide a
very flexible
measurement system. The
capabilities
of the overall system depend
mainly
upon the
plug-ins
that are chosen. The following
information
describes
the
techniques for making basic measurements.
These
applications are not described in
detail, since each
application
must be
adapted
to the requirements of the
individual
measurement.
Specific
applications for the
individual
plug-in
units are described in the manuals for
these units.
Contact your local
Tektronix Field Office or
representative for additional
assistance.
The
following books
describe oscilloscope measure
ment
techniques which can be adapted for use with this
instrument.
John
D. Lenk,
"Handbook
of
Oscilloscopes, Theory,
and Application",
Prentice-Hall
Inc., Englewood Cliffs,
New
Jersey,
1968.
J.
Czech,
"Oscilloscope
Measuring Techniques",
Springer-Verlag,
New York, 1965.
J.F.
Golding.
"Measuring
Oscilloscopes",
Transatlantic Arts,
Inc., 1971.
Charles
H. Roth Jr.,
"Use
of the
Oscilloscope",
A
programmed Text,
Prentice-Hall, Inc., Englewood
Cliffs,
New Jersey, 1970.
Chopped
Mode. The
Chop
position
of the time-base
unit Display
switch produces a display that is electronical
ly
switched between channels
at
a
100-kilohertz
rate. The
switching
sequence is
discussed earlier. In general, the
Chop
mode provides the best
display at sweep rates
slower
than
about one
millisecond/division or whenever
dual-trace,
single-shot phenomena are to be displayed. At
faster
sweep rates, the chopped switching becomes
apparent
and
may interfere with the display.
Peak-to-Peak
Voltage Measurements—AC
To
make peak-to-peak voltage measurements, use the
following procedure:
1. Set the input
coupling on the vertical plug-in unit to
Gnd
and
connect the signal to the input connector.
1-7
Содержание 5110
Страница 6: ...5110 Fig 1 1 5110 Oscilloscope 2134 01 ...
Страница 22: ......
Страница 34: ......
Страница 42: ......
Страница 83: ...5110 I43XII3 2134 15 ...
Страница 84: ... i 143 I132 2134 15 BLOCK DIAGRAM ...
Страница 85: ... t 2 E I 5110 S LNHNOdWOD BOVJHaiNI ...
Страница 88: ...J4 O3 INTERFACE J INTERFACE A NOV 1978 ...
Страница 92: ...AUXILIARY BOARD 1143 2134 18 AUXILIARY BOARD ...
Страница 95: ...DEFLECTION AMPLIFIERs ...
Страница 102: ...LV POWERSUPPLY CALIB COMPONENTS A 4 L V Power Supply circuit board 5110 ...
Страница 107: ...SIGNALS OUT OPTION 7 ONLY SI 10 OPT 7 213 26 REV A FE BI979 SIGNALS OUT COPTION T ONLY n ...
Страница 114: ......
Страница 115: ...5110 OSCILLOSCOPE ...
Страница 116: ...FIG 2 MAINFRAME p 5110 OSCILLOSCOPE ...
Страница 117: ...1 ...
Страница 121: ...o ...
Страница 122: ...S 1 5110 OSCILLOSCOPE ...
Страница 123: ...13 FIG 4 RACKMOUNT CABINET 5110 OSCILLOSCOPE ...
Страница 124: ......