Field or control
Description
Identifier High
Sets the frame identifier high pattern which, if exceeded, will cause a trigger.
Available when Trigger On = Identifier and Trigger When Data is set to Inside Range or Outside
Range.
Identifier Low
Sets the frame identifier low pattern which, if exceeded, will cause a trigger.
Available when Trigger On = Identifier and Trigger When Data is set to Inside Range or Outside
Range.
Cycle Count
Sets the cycle count pattern on which to trigger. Use in conjunction with the Trigger When field to
specify the exact trigger condition.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Cycle Count or Header Fields and Trigger When Data is not set to
Inside Range or Outside Range.
Cycle Count High
Sets the cycle count high limit which, if exceeded, will cause a trigger.
Available when Trigger On = Cycle Count and Trigger When Data is set to Inside Range or Outside
Range.
Cycle Count Low
Sets the cycle count low limit which, if exceeded, will cause a trigger.
Available when Trigger On = Cycle Count and Trigger When Data is set to Inside Range or Outside
Range.
Indicator Bits
Sets the indicator bits on which to trigger.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Header Fields .
Payload Length
Select the Binary, Hex, or Decimal field and use the A and B knobs to select and change the values.
Or double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Header Fields.
Header CRC
Select the Binary or Hex field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Header Fields.
Trigger When Data
Sets the trigger when data condition.
When set to Inside Range or Outside Range, fields are displayed to set a high and low boundary
pattern for the specified trigger type.
Available when Trigger On = Identifier or Identifier & Data.
Data Bytes
Sets the number of data bytes on which to trigger (one to sixteen bytes). Use the A knob to change the
value. Or double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = Data or Identifier & Data.