Programming by console
Installer Manual -
TP8-64 BUS
5-22
Setting
6
Vocal block
[ ]
•
Block all the channels
On reception of the blocking command, the control panel
checks if there are events queued up. If there are not or a
single type protocol has been programmed, it closes the
communication and blocks the phone call cycles of all the
vocal and digital channels associated to the event.
[ ]
Block the single channel
[ # ]
Block all the channels
z
Vocal block
Interruption of all the vocal calls by pressing the star key (*) on
the telephone dial during a vocal communication. On reception
of the blocking command, the control panel can:
•
Block the single channel
On reception of the blocking command, the control panel
closes the communication and blocks the active phone call
cycle of this channel.
•
Block all the channels
On reception of the blocking command, the control panel
closed the communication and blocks the phone call cycles
of all the vocal channels associated to the event.
[ ]
Block the single channel
[ # ]
Block all the channels
z
Digit. block
Interruption of all the active digital calls using non Tecnoalarm
protocols. On reception of the blocking command, the control
panel can:
•
Block the single channel
On reception of the blocking command, the control panel
checks if there are events queued up. If there are not or a
single type protocol has been programmed, it closes the
communication and blocks the active phone call cycle of
this channel. In all the other cases, the next event is
transmitted.
•
Block all the channels
On reception of the blocking command, the control panel
checks if there are events queued up. If there are not or a
single type protocol has been programmed, it closes the
communication and blocks the phone call cycles of all the
digital channels using non-Tecnoalarm protocols
associated to the event.
[ ]
Block the single channel
[ # ]
Block all the channels
z
Tecno block
Interruption of all the active digital calls using the Tecnoalarm
protocol. On reception of the blocking command, the control
panel can:
•
Block the single channel
On reception of the blocking command, the control panel
checks if there are events queued up. If there are not or a
single type protocol has been programmed, it closes the
communication and blocks the active phone call cycle of
this channel. In all the other cases, the next event is
transmitted.
•
Block all the channels
On reception of the blocking command, the control panel
checks if there are events queued up. If there are not or a
single type protocol has been programmed, it closes the
communication and blocks the phone call cycles of all the
digital channels using theTecnoalarm protocol associated
to the event.
[ ]
Block the single channel
[ # ]
Block all the channels
z
Opening msg
Enables the vocal opening message anticipating every voice
message transmitted.
z
Ring back
Permits enabling/disabling of the ring back check prior to
transmitting voice messages.
z
Rings
Defines after how many rings the control panel is to answer to
incoming calls (from 3 to 17).
Setting
7
Digit. block
[ ]
Setting
8
Tecno block [ ]
Setting
9
Opening msg [ ]
Setting
10
Ring back
[ ]
Setting
11
Rings
[ ]
Содержание TP8-64 BUS
Страница 4: ...IV Installer Manual TP8 64 BUS...
Страница 12: ...Index Installer Manual TP8 64 BUS 8...
Страница 16: ...Generalfeatures Installer Manual TP8 64 BUS 1 4...
Страница 32: ...Hardware Installer Manual TP8 64 BUS 2 16...
Страница 48: ...Input expansion modules Installer Manual TP8 64 BUS 2A 16...
Страница 54: ...Output expansion modules Installer Manual TP8 64 BUS 2B 6...
Страница 58: ...Console Installer Manual TP8 64 BUS 2C 4...
Страница 64: ...Keypoints Installer Manual TP8 64 BUS 2D 6...
Страница 70: ...Programming interfaces Installer Manual TP8 64 BUS 2E 6...
Страница 72: ...Telephone communicator with GSM module Installer Manual TP8 64 BUS 2F 2...
Страница 76: ...Wireless expansion modules Installer Manual TP8 64 BUS 2G 4 2G 2 2 DIP SWITCH SETTINGS TABLE 2 2G 2 3 CASING...
Страница 79: ...TP8 64 BUS Installer manual Wireless expansion modules 2G 7 2G 4 1 ELECTRONIC BOARD 2G 4 2 DIP SWITCH SETTINGS...
Страница 82: ...Wireless expansion modules Installer Manual TP8 64 BUS 2G 10...
Страница 88: ...Set up Installer Manual TP8 64 BUS 3 6...
Страница 93: ...TP8 64 BUS Installer Manual Set up 3 11 3 3 2 CONNECTION OF THE MODULES ON SENSOR BUS AND SIRENS BUS...
Страница 138: ...Programming by PC Installer Manual TP8 64 BUS 4 44...
Страница 176: ...Programming by console Installer Manual TP8 64 BUS 5 38...
Страница 180: ...Control by console Installer Manual TP8 64 BUS 6 4 OPERATIONS WITHOUT CODE...
Страница 192: ...Control by console Installer Manual TP8 64 BUS 6 16...
Страница 222: ...Technicalspecifications Installer Manual TP8 64 BUS 8 16...
Страница 223: ...TP8 64 BUS Installer Manual Protocols Appendix A A 1 APPENDIX A TRANSMISSION PROTOCOLS TP8 64 BUS...
Страница 224: ...Appendix A Protocols Installer Manual TP8 64 BUS A 2...
Страница 227: ...TP8 64 BUS Installer Manual Special procedures Appendix B B 1 APPENDIX B SPECIAL PROCEDURES TP8 64 BUS...
Страница 228: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 2...
Страница 240: ...Appendix B Special procedures Installer Manual TP8 64 BUS B 14...
Страница 241: ...TP8 64 BUS Installer Manual Code management Appendix C C 1 APPENDIX C CODE MANAGEMENT TP8 64 BUS...
Страница 242: ...Appendix C Code management Installer Manual TP8 64 BUS C 2...
Страница 245: ...TP8 64 BUS Installer Manual Code management Appendix C C 5...
Страница 246: ...Appendix C Code management Installer Manual TP8 64 BUS C 6 TP8 64 BUS INSTALLER MANUAL...