RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 3.17
•
Pulse signal
This is a square wave signal with frequency 50 Hz (T=20 msec) and 50% duty cycle generated
by the Hall sensor when the elevation motor moves. This signal enters the ALE/AT UL driver
(pins 6 and 4 of connector J7) and provides the feedback of the motor movement.
This signal alternates between a low value of 0 Vdc and a high value of 5 Vdc. When measured
with a multimeter, this signal is at either 0 or 5 Vdc when the motor is stopped, while during
motor movements it is approximately 2.5 Vdc.
In order to function correctly, the Hall sensor requires a +5 Vdc supply voltage which it
receives from the elevation board (pins 5 and 4 of connector J7).
•
Limit switch signal
The limit switch is a NC contact entering the ALE/AT UL driver (pins 3 and 8 of connector J8),
which opens when the machine pressed it during the power-on reset procedure.
Содержание EXCITE Run 500
Страница 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Страница 2: ......
Страница 4: ......
Страница 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Страница 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Страница 57: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 5 LEBANON DVB T URUGUAY DVB T PAL N LIBYA DVB T...
Страница 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Страница 60: ......
Страница 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Страница 148: ......
Страница 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Страница 218: ......
Страница 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Страница 230: ......
Страница 233: ......