RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.40
6.16.2.
H
AND SENSOR
The machine displays this error if the HS/HR receiver is not working, or if it is not supplied by the
display board.
For an easier and quicker diagnosis of the problem, we recommend to use the
functions of Test Box Excite.
THERE IS NO HR
SIGNAL
Are the sensors correctly
connected to the HS/HR
receiv er?
Is the v oltage at the output of
the display board correct ?
Reinstate the connection
Replace cable CU206
Replace the display board
2
4
YES
NO
YES
NO
Is the v oltage at the input to the
HS/HR receiv er correct?
Replace the HS/HR
receiv er
3
YES
NO
Check the wiring and earth
connection of the machine
1
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
Содержание EXCITE Run 500
Страница 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Страница 2: ......
Страница 4: ......
Страница 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Страница 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Страница 57: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 5 LEBANON DVB T URUGUAY DVB T PAL N LIBYA DVB T...
Страница 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Страница 60: ......
Страница 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Страница 148: ......
Страница 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Страница 218: ......
Страница 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Страница 230: ......
Страница 233: ......