RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.34
"GRADIENT NOT
WORKING" MESSAGE
ON THE DISPLAY
Verify the P09
parameter is correctly
setted.
1
2
Replace the
microswitch.
NO
NO
Setting P09=0,
turn off and on the machine.
The motor moves
(activates the splope)?
SI
The micro working properly?
SI
Verify during the movement, if
the impulse are present on the
J7 connector of the Driver
Board.
Replace the Driver
and
re-setting the P09=15
parameter.
NO
Verify if the voltage gardient of
the engine during the reset.
There is tension?
NO
Replace the slope
engine
and
re-setting the P09=15
parameter.
SI
Replace the Driver
and
re-setting the P09=15
parameter.
NO
3
Содержание EXCITE Run 500
Страница 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Страница 2: ......
Страница 4: ......
Страница 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Страница 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Страница 57: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 5 LEBANON DVB T URUGUAY DVB T PAL N LIBYA DVB T...
Страница 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Страница 60: ......
Страница 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Страница 148: ......
Страница 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Страница 218: ......
Страница 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Страница 230: ......
Страница 233: ......