RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.28
6.10.
THE DISPLAY SHOWS “PRESS A KEYS…”
This error message can be caused by:
•
loss of communication between the lower and upper assemblies;
•
the user has pressed the emergency button;
•
detective emergency button: the micro switch is opened.
To In order to reinstate normal operation, simply press any key. If communication between the
upper and lower assemblies is not immediately re-established, the message will remain on the
display while the machine continues trying for 30 seconds, after which the “THE EQUIPMENT IS
BLOCKED” message will appear.
The machine keeps count of the attempts to reinstate communication by incrementing the
COM.FAULT parameter, which can be viewed using the procedure described in paragraph 9.4.4.3
“COM.Fault”.
Содержание EXCITE Run 500
Страница 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Страница 2: ......
Страница 4: ......
Страница 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Страница 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Страница 57: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 5 LEBANON DVB T URUGUAY DVB T PAL N LIBYA DVB T...
Страница 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Страница 60: ......
Страница 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Страница 148: ......
Страница 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Страница 218: ......
Страница 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Страница 230: ......
Страница 233: ......