Operating the Equipment Locally — Remote Control Menu
Reference Guide: evolution 5000 E5780 and E5782 Encoder
Page 4-17
ST.RE.E10135.4
Selected Item
Options
Description
Ethernet Bandwidth:
Set a low and a high network
bandwidth setting.
Problems can be experienced with Ethernet control of the Encoder if the
available network bandwidth is low. The low bandwidth setting limits the packet
size, which can prevent problems with low bandwidth networks, but at the cost
of speed of communications.
SABus Address:
Set the SABus address of the
Encoder.
49 to 127
The SABus protocol is multi-drop, and has an address byte for differentiating
between the devices on the SABus (the address option).
The Encoder can be controlled via an RS-232 or RS-485 serial interface using
a SABus protocol (see ST.TS.E10074 for details). The SABus protocol is
multi-drop, and has an address byte for differentiating between devices.
RS-232 interface
Serial Protocol:
This selects how the Encoder
responds to commands.
RS-485 interface
1200 Baud
2400 Baud
4800 Baud
9600 Baud
19200 Baud
SABus Baud Rate:
Set the SABus Baud Rate.
38400 Baud
SABus Data Bits
This determines whether the SABus interface is expecting 8 data bits (1 stop
bit), or 7 data bits (2 stop bits).
Off
Port functions as before (i.e. respond to command as described in the “Remote
Control Protocol (RCP)”.
RS232 Remote
Control Port
The existing RS232 9-pin D-type port labelled “Remote Control” provides a
menu interface to control the Encoder.
Serial Menu Remote Control
This is for serial closed captions. Thus, if using the remote control port for menu control, serial CC’s must
go in via the RS232 data port). When selected, it is not possible to set SMPTE 333-M Port option to
Remote.
The serial menu system available via this serial port is similar to Telnet (i.e. front panel level menu
available via user name “general”, “password”.) The port is configured as follows:
- Serial Protocol: must be set to RS232
- SA Bus Baud-rate and SA Bus Data Bits: must be set to correspond to the settings on the serial
terminal connected to the port.
Содержание E5780
Страница 42: ...Options and Upgrades Page 3 4 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 176: ...Web Browser Interface Page 5 2 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 184: ...Web Browser Interface Page 5 10 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 210: ...Glossary Page A 12 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 232: ...Technical Specification Page B 22 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 236: ...Creating and Downloading a Logo Page D 2 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 248: ...Creating and Downloading a Logo Page D 14 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 250: ...Band Plans Page E 2 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 258: ...Audio Modes Page F 2 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 266: ...Audio Modes Page F 10 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 268: ...Accuracy of Frequency Sources Page G 2 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...
Страница 270: ...Use of Remux Card in ASTC Page H 2 Reference Guide evolution 5000 E5780 and E5782 Encoder ST RE E10135 4 BLANK...