Appendix B Fault Symptom Code (FSC) Dictionary
Tandberg Data M-Series User’s Guide
111
002D
FSC_MAC_ADDR_ERROR
MAC address could
not be validated and
must be
reprogrammed
Microcode
100%
002E
FSC_UNSUPPORTED_FP
VAR 1 front panels are
not supported
Microcode
100%
1000
FSC_FPGA_INIT_STUCK_
HI
FPGA INIT pin was
detected as being high
when it should have
been low
System
100%
1001
FSC_FPGA_INIT_NOT_HI
FPGA INIT pin was
detected as being low
when it should have
been high
System
100%
1002
FSC_FPGA_DONE_
STUCK_HI
FPGA DONE pin was
detected as being high
when it should have
been low
System
100%
1003
FSC_FPGA_DONE_NOT_
HI
FPGA DONE pin was
detected as being low
when it should have
been high
System
100%
2000
FSC_DLT_INIT_FAILED
DLT initialization
failed
Microcode
100%
2001
FSC_DRIVE_TIMEOUT_1
Drive time out waiting
for status (drive 1)
Drive
100%
2002
FSC_DRIVE_TIMEOUT_2
Drive time out waiting
for status (drive 2)
Drive
100%
2003
FSC_DRIVE_TIMEOUT_3
Drive time out waiting
for status (drive 3)
Drive
100%
2004
FSC_DRIVE_TIMEOUT_4
Drive time out waiting
for status (drive 4)
Drive
100%
FSC
Name
Description
FRU Name
Confidence %
Содержание MSERIES USER
Страница 1: ...Tandberg Data M Series User s Guide T6423045 03 A01 ...
Страница 10: ...Figures x Tandberg Data M Series User s Guide ...
Страница 12: ...Tables xii Tandberg Data M Series User s Guide ...
Страница 16: ...Preface xvi Tandberg Data M Series User s Guide ...
Страница 28: ...Chapter 1 Overview Library Features 12 Tandberg Data M Series User s Guide ...
Страница 90: ...Chapter 4 Performing Maintenance Operations Adjusting the Contrast 74 Tandberg Data M Series User s Guide ...
Страница 102: ...Chapter 5 Running Diagnostic Programs Running the Display Test 86 Tandberg Data M Series User s Guide ...
Страница 122: ...Appendix A Specifications SCSI Specifications 106 Tandberg Data M Series User s Guide ...
Страница 190: ...Index 174 Tandberg Data M Series User s Guide ...