Appendix A Specifications
SCSI Specifications
Tandberg Data M-Series User’s Guide
105
Table 13 Climate
Table 14 Compliance
and Certification
SCSI Specifications
1
LVD SCSI configurations have a maximum allowable bus length of 12
meters. To determine the cable length of the bus, measure the lengths of
the SCSI cables connecting each device to that bus and add those lengths
together. To that total length, add 12.25 inches (31.10 cm) for the internal
SCSI cable length of each SCSI tape drive.
Temperature
(Operating)
Temperature
(Non-Operating)
Temperature
+50°F to 104°F
(+10°C to +40°C)
-22°F to +122°F
(-30°C to +50°F)
Humidity
20% to 80%
non-condensing
5% to 90%
non-condensing
Altitude
-1,000 to +10,000 feet
(-300 to +3,000 meters)
-1,000 to +36,000 feet
(-300 to +11,000 meters)
Safety
CSA C22.2 950, UL 1950, EN 60950
EMC/RFI
FCC CFR 47-15J (level A), EN55022 (CISPR 22)
level B, EN55024 (CISPR 24), VCCI
Agency Markings
CE, VCCI, UL, FCC, CSA
Содержание MSERIES USER
Страница 1: ...Tandberg Data M Series User s Guide T6423045 03 A01 ...
Страница 10: ...Figures x Tandberg Data M Series User s Guide ...
Страница 12: ...Tables xii Tandberg Data M Series User s Guide ...
Страница 16: ...Preface xvi Tandberg Data M Series User s Guide ...
Страница 28: ...Chapter 1 Overview Library Features 12 Tandberg Data M Series User s Guide ...
Страница 90: ...Chapter 4 Performing Maintenance Operations Adjusting the Contrast 74 Tandberg Data M Series User s Guide ...
Страница 102: ...Chapter 5 Running Diagnostic Programs Running the Display Test 86 Tandberg Data M Series User s Guide ...
Страница 122: ...Appendix A Specifications SCSI Specifications 106 Tandberg Data M Series User s Guide ...
Страница 190: ...Index 174 Tandberg Data M Series User s Guide ...