8
5
Start-up
Before start-up,
check the following:
• The system main switch (if available) is switched on.
• The controller is switched on or supplied with power.
• All segments of the display are shown for a short time (page 7).
• The software number and version appear (e.g. 519803 / SW 1.01).
If the controller then switches to the normal display, or, in the case of initial start-up or factory reset, to the
start menu, the internal function test was successful.
When started for the first time or af-
ter a factory reset
BAS12 RESET
, the
commissioning menu will appear. This is
for setting the basic parameters.
1
2
Example:
Change the language;
ENGLISH
is active.
3.
To select
DEUTSCH
, for example,
press the
keys;
DEUTSCH
will flash.
4.
Confirm the selection with the
key. You can find further information
in section 7.9, page 23
COM01 LANGUAGE SELECTION
.
The next parameter,
BAS09 TIME
, is
jumped to automatically.
3
4
5.
Adjust
BAS09 TIME
using the keys
.
6.
The setting is confirmed with
and the next value will appear.
5
6
The device will be restarted
when set-up is finished.
Input can be canceled with the
key; the program then jumps to item 1. Important: The start-up menu must be carried out up to the
confirmation of the hydraulic variant and the restart.