SYMEO Local Positioning Radar System
Product Family LPR
®
-1DHP-200 – Product Documentation
Technical Data
Copyright © Symeo GmbH 2018
DOC.EDO.000341.WORK.EN_LPR-1DHP-200_Product-Documentation.docx
Page 69 of 71
10.2 Mode Dependent Technical Data
The following tables depict the technical data, which are dependent on the used Radar
Mode, the used Bandwidth Mode and your regional settings.
10.2.1
Primary Radar Mode
General Technical Data
ETSI Specific Technical Data
FCC Specific Technical Data
10.2.2
Secondary Radar Mode
General Technical Data
Bandwidth Mode
0,5 GHz
2 GHz
Measurement
accuracy
up to +- 10 mm
up to +- 5 mm
Repeatability
up to +- 6 mm
up to +- 3 mm
Measurement
rate
up to 350 Hz
up to 350 Hz
Bandwidth Mode
0,5 GHz
2 GHz
Measuring range
2 m to 50 m
1 m to 50 m
Bandwidth Mode
0,5 GHz
2 GHz
Measuring range
2 m to 50 m
1 m to 20 m
Bandwidth Mode
0,5 GHz
2 GHz
Measurement
accuracy
up to +- 10 mm
up to +- 5 mm
Repeatability
up to +- 6 mm
up to +- 3 mm