Measurement Details for Diversity Radar Mode
For diversity radar mode, you must enable the “
Diversity mode
” setting under the
Settings
->
Measurement details.
The following settings will additionally appear:
Diversity partner IP address
o
In diversity mode the unit will connect to the diversity partner at the specified IP
address.
Diversity partner sync channel
o
The sync channel of the diversity partner unit must also be specified. It is used
internally to verify data from the correct partner unit is received.
Device - Settings – Modem
In this menu, the following settings are available:
PPP Point to Point protocol connection
APN address
APN username
APN password
Device - Settings – Network Routes
In this menu, you can adapt the network routes.
Click the “+
add route
” button.
The dialog box “
add route
” will appear.
Press the „
add
route”
button.
Device - Settings – Relay
In this menu, the following setting are available:
Relay data output
o
Relay switch commands can be used to control relays at other LPR
®
units, e.g. at
LPR
®
-1D24 devices
If the “
Relay data output
” is enabled, the following settings will additionally appear:
Relay destination address
o
LPR
®
-B address of destination device where the relays are switched (hex value)
Zone 1 distance
o
Relays assigned to zone 1 will open when measured distance is below this value
Zone 2 distance
o
Relays assigned to zone 2 will open when measured distance is below this value
The virtual relays 1-4 can be assigned to switch according to system health, Zone 1 state or
Zone 2 state.