9.2.3
LPR®-1D24 Address
LPR® unit addresses are completely defined by a 16 bit value:
0
Reserved
Group-ID:
The Group-ID of the unit (1..1022)
Station-ID:
for Distance Data:
for Relays Switching Command:
The Station-ID of the unit (SID)
Master and Slave
SID is
always
2 (
SID = 2)
SID = 1 for Master und SID = 2 for Slave
Table 9.4: LPR®-1D24 address