SYMEO Local Positioning Radar System
Product Family LPR
®
-1DHP-200 – Product Documentation
Quick Setup
Copyright © Symeo GmbH 2018
DOC.EDO.000341.WORK.EN_LPR-1DHP-200_Product-Documentation.docx
Page 27 of 71
Follow the subsequent steps for proper installation of the radar units:
Mount a standard mounting bracket to one side of the measurement setup.
Mount the radar unit into the mounting bracket.
Repeat the first two steps on the other side of the measurement setup.
Carefully align both radar units to each other. To do so, it is recommended to use a laser
level fitted into the alignment aids. The laser dot should point to the other sensor for both
directions (Master -> Slave, Slave -> Master).
Fix the systems by tightening the screws of the mounting brackets and the pipe clamps
with the correct tightening torques.
Connect the power supply and Ethernet cable with the M12 connectors as specified in
chapter 4.3.1 and 4.3.2 to both stations. The Ethernet connection at the Slave unit is only
required for configuration and can be removed during operation. If removed install the
protective cap of the connector.
6
Quick Setup
This chapter gives a short introduction for the setup of the radar sensors with the help of the
WebUI. For detailed information on all possible settings, please refer to chapter 8.
6.1 Initial Setup
The following steps must be followed for the initial setup of all radar units:
Mount and align the radar units as outlined in chapter 5.
Connect the radar units to a power source (11 – 36V) and wait until booting is finished
(blue LED switches to red or green).
Connect the radar unit to a PC via Ethernet and open the Webinterface (WebUI) in a
Webbrowser (
http://192.168.1.99
). See chapter 7 for a detailed description.
Sign in to the WebUI (see chapter 8.2).
Choose country and regulatory authority.
6.2 Quick Setup for Primary Radar Mode
The following settings must be set in the WebUI for operation in primary radar mode:
Device -> Settings -> Measurement basics
o
Station mode = Primary
o
Bandwidth mode = Choose a bandwidth that fits your required range and accuracy
o
Channel block = Use recommended selection
o
Sync channel = different than any other LPR
®
-1DHP-200 sensor in range; for
neighboring measurement paths use only every fourth sync channel.