SYMEO Local Positioning Radar System
Product Family LPR
®
-1DHP-200 – Product Documentation
Device Setup via the Web User Interface
Copyright © Symeo GmbH 2018
DOC.EDO.000341.WORK.EN_LPR-1DHP-200_Product-Documentation.docx
Page 42 of 71
Device - Settings – Customer Protocol
In this menu, the following settings are available:
Mode of customer protocol
o
Interface to customer - either TCP or UDP
Port
o
Port of customer protocol binary XP (Integer number in range 1100..65535)
Protocol frame length
o
Frame length of customer protocol binary XP (Default value 47 bytes). Each data
packet is zero-padded to the selected protocol frame length before the data packet is
sent. (Integer number in range 47..100 byte)
Enable custom output interval
o
Enable a custom output interval of own distance. If disabled, the own measured
distance is output with the internal measurement rate.
Output interval of own distance
o
Output interval of own measured distance in milliseconds (Integer number in range
10..60000 ms)
Device - Settings – Forwarding
In this menu, the following settings are available:
LAN forwarder (must be first activated by the user)
o
Forward packages via LAN to connected LPR
®
-1D24 unit
The following extra options will be available after enabling LAN forwarding:
Destination IP address
o
Destination IP address of connected LPR
®
-1D24 unit
Enable custom forward interval
o
Enable a custom forward interval of own distance. If disabled, the own measured
distance is forwarded with measurement rate
Device - Settings – LAN
In this menu, the following settings are available:
Link type
Address Mode
IP-Address
Netmask
Gateway
Hostname
o
Local hostname, this name will also be offered to the DHCP server in DHCP mode
DNS
o
IP of name server (domain name system)
Syslog
o
IP of server for syslog messages
NTP Server
o
IP or hostname of time server (network time protocol)