SYMEO Local Positioning Radar System
Product Family LPR
®
-1DHP-200 – Product Documentation
Mounting
Copyright © Symeo GmbH 2018
DOC.EDO.000341.WORK.EN_LPR-1DHP-200_Product-Documentation.docx
Page 25 of 71
5
Mounting
5.1 General Mounting Instructions
Site-specific mounting instructions must be followed if available.
The more accurately the radar units and reflectors are aligned to each other, the better
the performance of the measurement setup will be in terms of accuracy and range.
The radar units and/or corner reflectors must move parallel to the radar beam in the
installation.
Ensure that the Fresnel Zone is free of obstacles.
Ensure that your measured distances lie in the specified measuring range (see chapter
10)
For primary and secondary radar mode (not for diversity radar mode) ensure that
reflective surfaces (e.g. walls, the roof, the floor, crane tracks) and other reflective objects
(e.g. poles, tubes, bridges, vehicles) have the recommended clearance to the center of
the radar beam that is in accordance with
Table 5.1 (see also
Figure 3.3 and Figure 3.4).
Table 5.1: Recommended clearance to reflective surfaces and objects.
5.2 Mounting for Primary Radar Mode
The Primary Radar Mode is available for Product Types LPR
®
-1DHP-
220-R and LPR
®
-1DHP-290.
Measuring
distance d in m
10
20
30
50
70
100
150
200
250
300
Recommended
clearance in m
0.2
0.5
0.7
1.1
1.6
2.2
3.3
4.4
5.5
6.6