background image

2-6

AS1010S-T User's Manual

Figure 2-3.  Installing the Server into a Rack

Installing the Server into the Rack

You should now have rails attached to both the chassis and the rack unit.  The next 

step is to install the server into the rack.  Do this by lining up the rear of the chas-

sis rails with the front of the rack rails.  Slide the chassis rails into the rack rails, 

keeping the pressure even on both sides (you may have to depress the locking 

tabs when inserting).  See Figure 2-3.  

When the server has been pushed completely into the rack, you should hear the 

locking tabs "click".  

Содержание AS-1010S-T

Страница 1: ...AS1010S T USER S MANUAL 1 0b SUPER ...

Страница 2: ...DIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPER MICRO COMPUTER SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARD...

Страница 3: ...pter provides a checklist of the main components included with the server system and describes the main features of the H8SSL i motherboard and the SC811FT 260 chassis which comprise the 1010S T Chapter 2 Server Installation This chapter describes the steps necessary to install the 1010S T into a rack and check out the server configuration prior to powering up the system If your server was ordered ...

Страница 4: ...ter when adding or removing processors or main memory and when reconfiguring the motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC811FT 260 server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing the system power supply and cooling fan Chapter 7 BIOS T...

Страница 5: ...v Preface Notes ...

Страница 6: ...1 2 4 Installing the System into a Rack 2 4 2 5 Checking the Motherboard Setup 2 8 2 6 Checking the Drive Bay Setup 2 10 Chapter 3 System Interface 3 1 Overview 3 1 3 2 Control Panel Buttons 3 1 Reset 3 1 Power 3 1 3 3 Control Panel LEDs 3 2 Overheat Fan Fail 3 2 NIC2 3 2 NIC1 3 3 HDD 3 3 Power 3 3 3 4 Serial ATA Drive Carrier LED 3 3 Chapter 4 System Safety 4 1 Electrical Safety Precautions 4 1 4...

Страница 7: ...ference 5 11 5 9 Connector Definitions 5 11 Primary ATX Power Connector 5 12 Secondary Power Connector 5 12 NMI Button 5 12 Power LED 5 12 HDD LED 5 13 NIC1 NIC2 LED 5 13 Overheat Fan Fail LED 5 13 Power Fail LED 5 13 Reset Button 5 14 Power Button 5 14 Universal Serial Bus USB0 1 5 14 Serial ATA Activity LEDs 5 14 USB2 3 Headers 5 15 Serial Ports 5 15 Fan Headers 5 15 Overheat LED 5 15 Power LED S...

Страница 8: ... SATA Drive Connections 5 22 Floppy Connector 5 22 IDE Connector 5 23 SATA Connectors 5 23 5 13 Enabling SATA RAID 5 24 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive Devices 6 1 6 2 Control Panel 6 2 6 3 System Fans 6 3 System Fan Failure 6 3 Replacing System Fans 6 3 6 4 Drive Bay Installation Removal 6 4 SATA Drive Installation 6 4 CD ROM and Floppy Drive Installation 6 6 6 5 Power Suppl...

Страница 9: ...Table of Contents ix Appendices Appendix A BIOS Error Beep Codes Appendix B BIOS POST Checkpoint Codes Appendix C System Specifications ...

Страница 10: ...Notes x AS1010S T User s Manual ...

Страница 11: ...erboard and chassis various hardware components may have been included with the 1010S T as listed below One 1 slim floppy drive FPD PNSC 02 01 One 1 slim CD ROM drive CDM TEAC 24 B Two 2 hot swap SATA drive carriers CSE PT10 B Two 2 SATA cables CBL 0044 One 1 SATA LED cable CBL 0056 One 1 air shroud CSE PT0113 Two 2 4 cm counter rotating fans FAN 0087 One 1 SATA backplane CSE SATA 810 One 1 CPU bac...

Страница 12: ...p to 4 GB of unbuffered ECC DDR400 333 SDRAM Memory can operate in either single or dual channel mode Low profile memory modules are required for use in the 1U form factor of the 1010S T Serial ATA A Serial ATA controller is incorporated into the ServerWorks HT 1000 chipset The Serial ATA drives in the 1010S T are hot swappable PCI Expansion Slots The H8SSL i has one 64 bit 133 MHz 3 3V PCI X slot ...

Страница 13: ...drive and up to two Ultra ATA 100 hard drives or ATAPI devices Onboard I O backpanel ports include one serial COM port two USB ports a VGA monitor port PS 2 mouse and keyboard ports and two GLAN RJ45 ports Other Features Other onboard features that promote system health include voltage monitors a chassis intrusion header auto switching voltage regulators chassis and CPU overheat sensors virus prot...

Страница 14: ...iagram Please see Chapter 5 for details ServerWorks HT 1000 AMD OpteronTM Processor 184 pin DIMMs 8x HT 1 6 GB sec 144 bit 200 400 MT s Rage XL GLAN 2 PCI X 133 MHz Slot UDMA100 USB 2 0 NS87427 Super I O PS 2 Kybd Mouse Floppy Disk Drive Serial Ports BIOS LPC Link SATA Ports 4 33 MHz Bus 33 MHz PCI Slots 2 133 MHz Bus ...

Страница 15: ...ork activity hard disk drive activity and overheat fan fail conditions The control panel also includes a main power button and a system reset button Rear I O Panel The SC811FT 260 is a 1U rackmount chassis Its I O panel provides one expan sion card slot one COM port two USB ports PS 2 mouse and keyboard ports a graphics port and two Gb Ethernet ports See Chapter 6 for details Cooling System The SC...

Страница 16: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Asia Pacific Address Super Micro Taiwan 4F No 232 1 Liancheng Rd Chung Ho 235 Taipei Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3991 Web Site w...

Страница 17: ...damaged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the 1010S T It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outle...

Страница 18: ...tached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more simul taneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of...

Страница 19: ...omised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate considerati...

Страница 20: ... Sections of the Rack Rails You should have received two rack rail assemblies with the 1010S T Each of these assemblies consist of two sections an inner fixed chassis rail that secures to the unit A and an outer fixed rack rail B that secures to the rail brackets A sliding rail guide sandwiched between the two should remain attached to the fixed rack rail see Figure 2 1 The A and B rails must be deta...

Страница 21: ...ce when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in place when fully extended from the rack This prevents the server from coming completely out of the rack when you pull it out for servicing Installing the Rack Rails Determine where you want to place the 1010S T in the rack see Rack and Server Precautions in Section 2 3 Position...

Страница 22: ...e next step is to install the server into the rack Do this by lining up the rear of the chas sis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting See Figure 2 3 When the server has been pushed completely into the rack you should hear the locking tabs click ...

Страница 23: ... type rack follow the directions given on the previous pages for rack installation The only difference in the installation procedure will be the positioning of the rack brackets to the rack They should be spaced apart just enough to accomodate the width of the telco rack Figure 2 4 Installing the Server into a Telco Rack ...

Страница 24: ...processor You may have a processor already installed to the system board The processor should have a heatsink attached See Chapter 5 for instructions on processor and heatsink installation 3 Check the system memory Your 1010S T server system may have come with system memory already installed Make sure all DIMMs are fully seated in their slots For details on adding system memory refer to Chapter 5 ...

Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System ...

Страница 26: ... system 3 Check the Serial ATA disk drives Depending upon your system s configuration your system may have one or two Serial ATA drives already installed If you need to install Serial ATA drives please refer to the appropriate section in Chapter 6 4 Check the airflow Airflow is provided by two 4 cm counter rotating fans The system component layout was carefully designed to promote sufficient airflow th...

Страница 27: ...trol panel This chapter explains the meanings of all LED indicators and the appropriate response you may need to take 3 2 Control Panel Buttons There are two push button buttons located on the front of the chassis These are in order from left to right a reset button and a power on off button RESET The reset switch reboots the system POWER This is the main power switch which is used to apply or tur...

Страница 28: ...ion which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to make sure that the chassis covers are installed Finally verify that the heatsinks are installed properly see Chapter 5 This LED will remain flashing or on as long as th...

Страница 29: ... system s power supply units This LED should normally be illuminated when the system is operating 3 4 Serial ATA Drive Carrier LED Each Serial ATA drive carrier has a green LED When illuminated this green LED on the front of the Serial ATA drive carrier indicates drive activity ...

Страница 30: ...3 4 AS1010S T User s Manual Notes ...

Страница 31: ...em with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits another person who is familiar with the power off controls should be nearby to switch off the power if necessary Use only one hand when working with powered on electrical equipment This is to avoid making a complete circuit which will cause e...

Страница 32: ...which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Motherboard Battery CAUTION There is a danger of explosion if the onboard battery is installed upside down which will reverse its polarites see Figure 4 1 This battery must be replaced only with the same or an equivalent type recomme...

Страница 33: ...use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only do not touch its components peripheral chips memory modules or contacts When handling chips or modules avoid touching their pins Put the motherboard and...

Страница 34: ... the chassis cover is in place when the 1010S T is operating to assure proper cooling Out of warranty damage to the 1010S T system can occur if this practice is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER BATTERY HOLDER LITHIUM BATTERY OR ...

Страница 35: ...hat the size and weight of the motherboard can cause it to bend if handled improperly which may result in damage To prevent the moth erboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from static discharge Precautions Use a grounded wrist strap designed to prevent static discharge Tou...

Страница 36: ...ake sure that the metal standoffs click in or are screwed in tightly 1 Check the compatibility of the motherboard ports and the I O shield The H8SSL i motherboard requires a chassis that can support extended ATX boards of 8 x 12 in size such as the SC811FT 260 Make sure that the I O ports on the motherboard align with their respective holes in the I O shield at the rear of the chassis 2 Mounting t...

Страница 37: ...ket which may damage the CPU and or the socket Triangles 4 With the CPU inserted into the socket inspect the four corners of the CPU to make sure that it is properly installed and flush with the socket 5 Gently press the CPU socket lever down until it locks in the plastic tab Installing the Heatsink A heatsink should be installed to the processor You will have to remove the air shroud to install Se...

Страница 38: ... that the CPU backplate standoffs insert through the holes on the heatsink retention module and the four feet on the module contact the motherboard Secure the retention module to the backplate with the two screws provided Note BKT 0005 is included for use with third party heatsinks only When installing proprietary heatsinks SNK P0012 only BKT 0004 CPU backplate is needed The BKT 0005 retention mod...

Страница 39: ...ake sure the red wires connect to the pin 1 locations If you are configuring the system keep the airflow in mind when routing the cables The following data cables with their motherboard connector locations noted should be connected See the motherboard layout diagram in this chapter for connector locations CD ROM cable IDE 1 Floppy Drive cable Floppy SATA cable SATA0 SATA1 Control Panel cable JF1 see...

Страница 40: ...ite sides of each header All JF1 wires have been bundled into single keyed ribbon cable to simplify their connection The red wire in the ribbon cable plugs into pin 1 of JF1 Connect the other end of the cable to the Control Panel printed circuit board located just behind the system status LEDs in the chassis See the Connector Definitions section in this chapter for details and pin descrip tions of ...

Страница 41: ...ert each memory module vertically into its slot beginning with CPU1 slot 1A then 2A etc Pay attention to the notch along the bottom of the module to prevent inserting the module incorrectly see Figure 5 4 See support information below 2 Gently press down on the memory module until it snaps into place Note each processor has its own built in memory controller so CPU2 DIMMs cannot be addressed if on...

Страница 42: ... and on the bottom of the DIMM These prevent the DIMM from being installed incorrectly Support The H8SSL i supports single or dual channel unbuffered ECC DDR400 333 SDRAM Both interleaved and non interleaved memory are supported so you may populate any number of DIMM slots Low profile memory should be used in the 1U server chassis Populating two adjacent slots at a time with memory modules of the s...

Страница 43: ...sure it is supported by the riser card see step 1 above Begin by pulling the locking tab downward to unlock the bracket that covers the slot then remove the bracket Insert the PCI card into the riser card pushing down with your thumbs evenly on both sides of the card When the card is correctly installed finish by pushing the locking tab upward to secure the card in the system Note the PCI slot shie...

Страница 44: ...ttery JBT1 LAN2 LAN1 USB0 1 Rage XL 1U IPMI HT 1000 IDE 1 Floppy SATA0 JF1 CPU1 DIMM 2B CPU JPL J1 VGA PW1 FAN5 FAN1 JP1 JP2 PW2 CPU1 DIMM 1B CPU1 DIMM 2A CPU1 DIMM 1A JD1 Speaker FAN2 FAN3 PCI 6 133 MHz PCI X PCI 5 33 MHz PCI PCI 4 33 MHz PCI BIOS JPXISMB1 JPCISMB1 JPXA1 FAN4 JL1 JWOL J5 JWOR JWD USB2 3 COM2 SATA1 SATA2 SATA3 JPG1 JS9 COM1 JOH1 JP11 DP1 DP2 DP3 DP4 ...

Страница 45: ...COM1 COM2 COM1 Serial Port Header FAN1 5 Fan Headers Floppy Floppy Disk Drive Connector IDE 1 IDE Connector J1 Keyboard Mouse Ports J5 IPMI Header JD1 Power LED Speaker Header JF1 Front Panel Connector JL1 Chassis Intrusion Header JOH1 Overheat Warning Header JP1 Power Supply Fail Signal Header JP11 Power Supply Fail Alarm Reset Header JS9 Serial ATA LED Activity Header JWOL Wake On LAN Header JWO...

Страница 46: ... for pin definitions NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 Refer to the table on the right for pin definitions NMI Button Pin Definitions JF1 Pin Definition 19 Control 20 Ground Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table on the right for pin definitions Power LED Pin Definitions JF1 Pin Definition 15 Vcc 16 C...

Страница 47: ...2 Network Interface Control ler LED connection is located on pins 9 and 10 of JF1 Attach the NIC2 LED cable to display network activity Refer to the table on the right for pin definitions OH Fan Fail LED Pin Definitions JF1 Pin Definition 7 Vcc 8 Control Power Fail LED Pin Definitions JF1 Pin Definition 5 Vcc 6 Control NIC1 LED Pin Definitions JF1 Pin Definition 11 Vcc 12 NIC1 Active NIC2 LED Pin Definiti...

Страница 48: ...ions Power Button Pin Definitions JF1 Pin Definition 1 PW_ON 2 Ground Universal Serial Bus Ports Pin Definitions USB0 1 USB0 Pin Definition USB1 Pin Definition 1 5V 1 5V 2 PO 2 PO 3 PO 3 PO 4 Ground 4 Ground Reset Button The Reset Button connection is lo cated on pins 3 and 4 of JF1 Attach it to the hardware reset switch on the computer case Refer to the table on the right for pin definitions Reset Butt...

Страница 49: ...n the mother board near the COM2 header These may be connected to provide front side USB access USB cables not included are needed for the connec tions See the table on the right for pin definitions Extra Universal Serial Bus Headers Pin Definitions USB2 3 USB2 Pin Definition USB3 4 Pin Definition 1 5V 1 5V 2 PO 2 PO 3 PO 3 PO 4 Ground 4 Ground 5 Key 5 No connection Overheat LED JOH1 Connect an LED to...

Страница 50: ... Wake On Ring The Wake On Ring header is desig nated JWOR This function allows your computer to receive and wake up by an incoming call to the modem when in suspend state See the table on the right for pin definitions You must have a Wake On Ring card and cable to use this feature Wake On Ring Pin Definitions JWOR Pin Definition 1 Ground Black 2 Wake up PS 2 Keyboard and Mouse Port Pin Definitions J1 ...

Страница 51: ...he PWR_LED pin to indicate a power failure See the table on the right for pin definitions Power Supply Fail Alarm Header Pin Definitions JP1 Pin Definition 1 P S 1 Fail Signal 2 P S 2 Fail Signal 3 NC 4 Reset from MB Note This feature is only available when using redundant power supplies Power Supply Fail Alarm Reset Header Connect JP11 to the alarm reset but ton on your chassis if available or to a ...

Страница 52: ...r is off the pins CMOS Clear JBT1 is used to clear CMOS and will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First power down the system and unplug the power cord s 2 With the power disconnected short the CMOS pads with a metal object such as a small screwdriver for at least four seconds 3 Remov...

Страница 53: ... Disable JPG1 allows you to enable or disable the VGA port The default position is on pins 1 and 2 to enable VGA See the table on the right for jumper set tings VGA Enable Disable Jumper Settings JPG1 Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled LAN Enable Disable Change the setting of jumper JPL to enable or disable the LAN1 and LAN2 Gb Ethernet ports See the table on the right for...

Страница 54: ...ins 2 3 NMI Open Disabled Note When enabled the user needs to write their own application software in or der to disable the Watch Dog Timer Power Force On JP2 allows you to enable or disable the Power Force On function If enabled system power will always stay on If disabled the default setting the user needs to depress the power button to power up the system Power Force On Jumper Settings JP2 Jump...

Страница 55: ...te the speed of the connection See the table on the right for the functions indicated by with the connection speed LED LAN LED Connection Speed Indicator LED Color Definition Off 10 MHz Green 100 MHz Amber 1 GHz SATA Activity LEDs When illuminated the DP1 DP2 DP3 and DP4 LEDs indicate activity on SATA channels SATA3 SATA2 SATA1 and SATA0 respectively SATA Activity LEDs DP1 DP3 State System Status O...

Страница 56: ... should be used to take advantage of the speed this new technology offers The blue connector connects to the onboard IDE connector interface and the other connector s to your hard drive s Consult the documentation that came with your disk drive for details on actual jumper locations and settings for the hard disk drive Floppy Drive Connector Pin Definitions Floppy Pin Definition Pin Definition 1 GND ...

Страница 57: ...3 Host Data 2 14 Host Data 13 15 Host Data 1 16 Host Data 14 17 Host Data 0 18 Host Data 15 19 Ground 20 Key 21 DRQ3 22 Ground 23 I O Write 24 Ground 25 I O Read 26 Ground 27 IOCHRDY 28 BALE 29 DACK3 30 Ground 31 IRQ14 32 IOCS16 33 Addr1 34 Ground 35 Addr0 36 Addr2 37 Chip Select 0 38 Chip Select 1 39 Activity 40 Ground SATA Connectors There are no jumpers to con figure the SATA connectors which a...

Страница 58: ...IDE hard drive If on a separate IDE drive skip ahead to section entitled Enabling SATA RAID in the BIOS If you wish to have the OS on a SATA RAID array you must first complete the step below Building a Driver Diskette You must first build a driver diskette from the Super Micro CD ROM that was includ ed with the system You will have to create this disk on a computer that is already running and with t...

Страница 59: ...in windows as shown in Figure 5 6 The Disks window on the right will list all available drives The procedure below outlines the steps necessary to create a RAID array as seen in the Main Menu window of the RAID utility In each step note the Available Keys window in the bottom right of the screen These are the keys used to perform the various functions in each step Initialize Disks s The first step ...

Страница 60: ... Computer icon and then on the icon representing your CD ROM drive Finally double click on the S Setup icon Click the icons showing a hand writing on paper to view the readme files for each item Click the tabs to the right of these in order from top to bottom to install each item one at a time After installing each item you must reboot the system before moving on to the next item on the list You sh...

Страница 61: ...Chapter 5 Advanced Motherboard Setup 5 27 Figure 5 7 Driver Installation Display Screen ...

Страница 62: ...5 28 AS1010S T User s Manual Notes ...

Страница 63: ...ery carefully The following measures are generally sufficient to protect your equipment from ESD discharge Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modul...

Страница 64: ...ese wires have been bundled together in a ribbon cable to simplify the connection Connect the cable from JF1 on the motherboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons Details on JF1...

Страница 65: ... fan at your earliest convenience with the same type and model the system can continue to run with a failed fan Remove the top chassis cover refer to page 6 7 while the system is still running to determine which fan unit has failed then power down the system to replace it Removing the power cord s is also recommended as a safety precaution Replacing System Cooling Fans 1 Removing a fan With the sy...

Страница 66: ...n with those in the carrier Secure the drive to the carrier with four screws as shown in Figure 6 3 Figure 6 3 Mounting a Drive in a Carrier 6 4 Drive Bay Installation Removal Accessing the Drive Bays Serial ATA Drives Because of their hotswap capability you do not need to access the inside of the chassis or power down the system to install or replace Serial ATA drives Proceed to the next step for...

Страница 67: ...installation and removal These drives are hot swappable meaning they can be installed and removed without powering down the system To remove first push the release button located beside the drive LEDs then swing the colored handle fully out and use it to pull the unit straight out see Figure 6 4 Important Regardless of how many Serial ATA drives are installed both drive carriers must remain in the ...

Страница 68: ...s you will hear a click Next depress the two buttons on the top of the chassis to release the top cover and at the same time push the cover away from you until it stops You can then lift the top cover from the chassis to gain full access to the inside of the server To install either type of drive start by disconnecting the drives power and data cables then remove the two screws from either side of...

Страница 69: ...ssis to release the top cover and push it away from you You can then lift the top cover from the chassis to gain full access to the inside of the server 2 Removing the power supply First unplug the power cord from the system To remove the failed power unit remove the two screws on the back of the power supply which secure it to the chassis You can then lift the unit straight out of the chassis The...

Страница 70: ...6 8 AS1010S T User s Manual Notes ...

Страница 71: ...1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The right frame displays the key legend Above the key legend is an area reserved for a text mes sage When an option is selected in the left frame it is highlighted in white Often a text message ...

Страница 72: ...e keyboard Press the Tab key or the Arrow keys to move between fields The date must be entered in DAY MM DD YYYY format The time is entered in HH MM SS format Please note that time is in a 24 hour format For example 5 30 A M appears as 05 30 00 and 5 30 P M as 17 30 00 7 3 Advanced Settings Menu CPU Configuration Sub Menu GART Error Reporting This setting is used for testing only MTRR Mapping This d...

Страница 73: ... 137 GB your system must be equipped with 48 bit LBA mode addressing If not contact your manufacturer or install an ATA 133 IDE controller card that supports 48 bit LBA mode The options are Disabled and Auto Block Multi Sector Transfer Block mode boosts IDE drive performance by increasing the amount of data transferred Only 512 bytes of data can be transferred per interrupt if block mode is not us...

Страница 74: ...disk drives such as IDE CD ROM drives check the specifications of the drive DMA Mode Select the DMA mode of the drive Options are SWDMA0 SWDMA1 SWD MA2 MWDMA0 MWDMA1 MWDMA2 UDMA0 UDMA1 and UDMA2 S M A R T Self Monitoring Analysis and Reporting Technology SMART can help predict impending drive failures Select Auto to allow BIOS to auto detect hard disk drive support Select Disabled to prevent AMI BI...

Страница 75: ... address The options are Yes and No Palette Snooping Select Enabled to inform the PCI devices that an ISA graphics device is installed in the system in order for the graphics card to function properly The options are Enabled and Disabled PCI IDE BusMaster Set this value to allow or prevent the use of PCI IDE busmastering Select Enabled to allow AMI BIOS to use PCI busmaster for reading and writing...

Страница 76: ... set to Disabled the serial port physically becomes unavailable Select 2F8 IRQ3 to allow the serial port to use 2F8 as its I O port address and IRQ 3 for the interrupt address The options are Disabled 2F8 IRQ3 3E8 IRQ4 and 2E8 IRQ3 Serial Port 2 Mode Tells BIOS which mode to select for serial port 2 The options are Normal Sharp IR SIR and Consumer IRQ3 IRQ4 IRQ5 IRQ7 IRQ9 IRQ10 IRQ11 IRQ14 IRQ15 T...

Страница 77: ...ting determines how the memory clock is set Auto has the memory clock set by the code and Limit allows the user to set a standard value MCT Timing Mode Sets the timing mode for memory Options are Auto and Manual User Configuration Mode Options are Auto and Manual Bank Interleaving This setting is used to determine whether bank interleaving is to be employed The options are Auto and Disabled Burst L...

Страница 78: ...Enabled and Disabled ECC Chip Kill Allows the user to Enable or Disable ECC Chip Kill DRAM Scrub Redirect Allows system to correct DRAM ECC errors immediately even with background scrubbing on Options are Enabled and Disabled DRAM BG Scrub Corrects memory errors so later reads are correct Options are Dis abled and various times in nanoseconds and microseconds L2 Cache BG Scrub Allows L2 cache RAM ...

Страница 79: ...er Display This setting is used to Enable or Disable the banner display INT13 Support This setting is used to Enable or Disable the INT13 function ACPI Configuration Advanced ACPI Configuration ACPI Version Features Select which version of ACPI you wish to use Options are ACPI v 1 0 ACPI v 2 0 and ACPI v 3 0 ACPI APIC Support Select Enabled to allow the ACPI APIC Table Pointer to be included in the ...

Страница 80: ...ent Log This setting will clear all event logs when set to OK The options are OK and Cancel Event Log Statistics Highlight this item and press Enter to view details on the count of total unread events MPS Configuration MPS Revision This setting allows the user to select the MPS revision level The options are 1 1 and 1 4 Remote Access Configuration Remote Access Use this setting to Enable or Disable ...

Страница 81: ...ting is 78o C The other items in the submenu are all systems monitor displays for the follow ing information System Temperature CPU1 Vcore 5 Vin 12Vin 12V Vcc DRAM VTT 1 2V for Hyper Transport 5V standby 2 5V standby and battery voltage System Fan Monitor Fan Speed Control Modes This feature allows the user to determine how the system will control the speed of the onboard fans If the option is set...

Страница 82: ... boot up If Enabled this display the OEM logo instead of POST messages Add On ROM Display Mode This setting controls the display of add on ROM read only memory messages Select Force BIOS to allow the computer system to force a third party BIOS to display during system boot Select Keep Current to allow the computer system to display the BIOS information during system boot Boot up Num Lock Set this ...

Страница 83: ...Drive 3rd Drive 4th Drive 5th Drive Specify the boot sequence for the available hard drives on the system Removable Drives This feature allows the user to specify the Boot sequence from available remov able drives 1st Drive Specifies the boot sequence for the 1st Removable Drive Hit DEL Message Display Enable to display the message telling the user to hit the DEL key to enter the setup utility The ...

Страница 84: ...y Setup screen Select Disabled to deactivate the Boot Sector Virus Protection Select Enabled to enable boot sector protection When Enabled AMI BIOS displays a warning when any program or virus issues a Disk Format command or attempts to write to the boot sector of the hard disk drive The options are Enabled and Disabled CD DVD Drives This feature allows the user to specify the boot sequence from a...

Страница 85: ...eboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Discard Changes Select this option and press Enter to discard all the changes and return to AMI BIOS Utility Program Load Optimal Defaults To set this feature select Load Optimal Defaults from the Exit menu and press Enter Then Select OK to allow BIOS to automatically load the Optimal Defaults as the BIOS Setting...

Страница 86: ...7 16 AS1010S T User s Manual Notes ...

Страница 87: ...t with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed with the exception of Beep Code 8 are fatal errors Appendix A BIOS Error Beep Codes A 1 A 1 AMIBIOS Error Beep Codes Beep Code Erro...

Страница 88: ...A 2 AS1010S T User s Manual Notes ...

Страница 89: ...s are listed in order of execution Checkpoint Code Description D0h The NMI is disabled Power on delay is starting Next the initialization code check sum will be verified D1h Initializing the DMA controller performing the keyboard controller BAT test starting memory refresh and entering 4 GB flat mode next D3h Starting memory sizing next D4h Returning to real mode Executing any OEM patches and settin...

Страница 90: ...red while reading the floppy drive in drive A F0h Next searching for the AMIBOOT ROM file in the root directory F1h The AMIBOOT ROM file is not in the root directory F2h Next reading and analyzing the floppy diskette FAT to find the clusters occupied by the AMIBOOT ROM file F3h Next reading the AMIBOOT ROM file cluster by cluster F4h The AMIBOOT ROM file is not the correct size F5h Next disabling internal...

Страница 91: ...d during power on Initializing CMOS RAM if the Initialize CMOS RAM in every boot AMIBIOS POST option was set in AMIBCP or the End key was pressed 12h Next disabling DMA controllers 1 and 2 and interrupt controllers 1 and 2 13h The video display has been disabled Port B has been initialized Next initializing the chipset 14h The 8254 timer test will begin next 19h Next programming the flash ROM 1Ah T...

Страница 92: ... general devices next if present See the last page of this chapter for additional information 39h Displaying bus initialization error messages See the last page of this chapter for additional information 3Ah The new cursor position has been read and saved Displaying the Hit DEL mes sage next 3Bh The Hit DEL message is displayed The protected mode memory test is about to start 40h Preparing the des...

Страница 93: ... was adjusted for relocation and shadowing Clearing the Hit DEL message next 59h The Hit DEL message is cleared The WAIT message is displayed Starting the DMA and interrupt controller test next 60h The DMA page register test passed Performing the DMA Controller 1 base register test next 62h The DMA controller 1 base register test passed Performing the DMA controller 2 base register test next 65h T...

Страница 94: ...ntrol and has now returned control to BIOS POST Perform ing any required processing after the option ROM returned control 99h Any initialization required after the option ROM test has completed Configuring the timer data area and printer base address next 9Ah Set the timer and printer base addresses Setting the RS 232 base address next 9Bh Returned after setting the RS 232 base address Performing a...

Страница 95: ...0 option ROM had control next Aah Initialization after E000 option ROM control has completed Displaying the system configuration next Abh Uncompressing the DMI data and executing DMI POST initialization next B0h The system configuration is displayed B1h Copying any code to specific areas 00h Code copying to specific areas is done Passing control to INT 19h boot loader next ...

Страница 96: ...B 8 AS1010S T User s Manual Notes ...

Страница 97: ...o4GBofunbufferedECCDDR400 333 low profile SDRAM Note See the memory section in Chapter 5 for details Serial ATA Controller ServerWorks on chip controller SATA IDE Drive Bays Two 2 hot swap drive bays for 3 5 hard drives hot swap for SATA only Peripheral Drive Bays One 1 floppy drive One 1 slim CD ROM drive Expansion Slots provided with included riser card One 1 riser card to support the use of one f...

Страница 98: ...art PWS 0055 Rated Output Voltages 3 3V 15A 5V 25A 12V 18A 12V 1A 5Vsb 2A BTU Rating 1400 BTUs hr for rated output power of 260W Operating Environment Operating Temperature 10º to 35º C 50º to 95º F Non operating Temperature 40º to 70º C 40º to 158º F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emis...

Страница 99: ...V Certified Germany CE Marking Europe California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate ...

Страница 100: ...C 4 AS1010S T User s Manual Notes ...

Отзывы: