3.3.8 Accumulator
Warning:
The accumulator is charged with
high-pressure nitrogen gas. Improper
operation may lead to explosion and
result in serious injury or damage.
When handling accumulator, always follow the
steps below.
The pressure in control piping could not be
completely released. When disassembling
hydraulic devices, do not stand in the oil
ejecting direction. Loosen the bolts gradually.
Do not disassemble accumulator.
Do not place the accumulator close to naked
flame or get it exposed in fire.
Do not drill holes or weld on accumulator.
Do not get accumulator hit, rolled or shocked.
When handling accumulator, it’s necessary to
bleed the air. Please contact distributor.
The accumulator is fixed in control piping. The
accumulator is a device being used to store
pressure. With this accumulator equipped, you are
allowed to operate controlling piping in a short
time, even if engine stops. Therefore, work
equipments could be lowered under their own
weight by means of control lever.
Releasing pressure on a machine equipped
with accumulator.
Lower the work equipment on the ground, turn
off its breaker or other accessories.
Stop the engine.
Shift starting switch to ON position to flow the
circuit current.
Set safety lock lever to free position. Operate
work equipment lever and accessory control
pedal forward, backward, leftward and
rightward alternately to release pressure in
piping.
Set safety control lever to LOCK position to
lock up control lever and accessory pedals.
Содержание SWE150F
Страница 19: ...12 18 No unauthorized access label Warning Stay clear of operation area of working device...
Страница 22: ...15 23 Gravity label 24 Hydraulic oil label 25 Greasing...
Страница 151: ...144 4 4 9 Hose...
Страница 193: ...186 5 Technical specification...
Страница 197: ...190 5 1 4 Circuit diagram...
Страница 199: ...192 5 1 6 Hydraulic diagram...
Страница 204: ...197 5 2 4 SWE210F Circuit diagram...
Страница 206: ...199 5 2 6 Hydraulic diagram...