169
4.5.6.3 Check, adjust air conditioning
compressor belt tension.
Inspection
The deflection should be 5 to 8mm, when
pressing at a point midway between drive belt
pulley and compressor belt pulley with a finger
pressure of 58.8N(6kgf).
Adjust
Loosen bolts (1).
Pull adjusting screw blot
(
2
)
, make
deflection of belt to be 5-8 mm
(
about 58.8N
(
6 kgf
))
.
Fasten bolts (1).
Check if belt pulley is broken, and if V groove
and V belt are wearing. Especially inspect V
belt do not contact with bottom of V groove.
If belt is stretched, and has no adjusting
allowance or cut or split exits, please change
belt.
When adjusting new belt, after one hour’s
operation, please adjust it again.
(