When the existing system is enabled, the upper limit of optimized power is
the sum of the rated power of the hybrid inverter and the rated power of the
existing PV system.
Once the optimized mode is enabled, the DO relay will not disconnect until
20 minutes after the DO connection.
Take 09:00 am–09:30 am and the optimized power of 1000 W as an example.
3000W
2000W
1000W
Charging
PV generation
Grid
Contactor
09:00 am
–
09:30 am
DO relay
ON1
COM1
Inverter
DO port
Fig. 10-4
DO Operation in Optimized Control
10.4.12 Setting the Communication Parameters
Ethernet:
−
The communication address ranges from 1 to
247.
−
The IP, sub net, gateway, DNS1 and DNS2
can be modified only when the DHCP is set to
OFF.
Comm. Param
Ethernet Config
WiFi Config
−
Acquire the IP, subnet mask, gateway, DNS1 and DNS2 from the
network professional.
−
Set the Server to “CLOUD” if the data is uploaded to
192.168.100.002
Gateway
:
Con-Server
[ON]
DNS
[ON]
001.002.004.008
DNS2
008.008.008.008
DNS1
IP:
192.168.001.100
Sub Net
:
255.255.000.000
Press
DHCP
[ON]
Addr
001
Port
502
Press
Press
Server
[CLOUD]
Wi-Fi:
Quick Configuration:
Press
ENT
to enable this
function and then you can connect the inverter Wi-Fi
to your home router quickly with the iSolarCloud
App.
WiFi Config
Quick Config
WiFi Factory Reset