User Manual
92
The cable for connecting to the DRED is not included in the delivery.
Use a TIA/EIA 568B standard network cable with a diameter of 3 mm–5.3 mm.
Procedure
1.
Unscrew the swivel nut from
any
Com.
port.
2.
Lead the cable through the
cable gland, as shown below.
3.
Remove the cable jacket by 40 mm to 50 mm and strip the wire
insulation by 5 mm–7 mm.
4.
Plug the wires into the corresponding terminals without tool tightening,
as shown below.
Note:
For reconnection, press the part as shown in the red circle so as to
pull out the cable.
Corresponding Relationship Between
Cables and Pins:
Pin 1: White-orange; Pin 2: Orange;
Pin 3: White-green; Pin 4: Blue;
Pin 5: White-blue; Pin 6: Green;
DRM Termianls
DRM
5.
Fasten the swivel nut and connect the other end to the DRED.
12.1.2 Viewing the DRM State via LCD Menu
When the inverter is running with the demand respond commands, the DRM
which is being performed by the inverter will be display on LCD screen.