10.4.8 Setting Reactive Power Regulation
For details, see
step 4
in “
” and the section
.
10.4.9 Setting Active Power Response
For details, see
.
10.4.10 Setting Limit Power Ramp
The limit power ramp function is disabled by
default.
Enable
: when there is a change in the PV input
power, the output power through the
grid-connected point will change with a ramp,
but not suddenly.
Limit P Ramp
Disable
Enable
10.4.11 Setting Load Control
After connecting the load to the DO terminals, a relay control signal will be
transmitted. Users can flexibly set the control mode via the LCD menu.
Press
/
to choose the control mode.
Press
ENT
to confirm.
Load Control
Timer
ON/OFF
Optimized
1/2
Timer Control
In this mode, set the Start time and
End time, the system will control the
load operation during the interval.
Take 09:00 am–09:30 am as an
example.
Load Control
Timer
ON/OFF
Optimized
Start Time1
End Time1
09:00
09:30
Start Time2
End Time2
09:00
09:30