Sun StorEdge T3 and T3+ Array Field Service Manual • September 2001
FIGURE 4-1
Sun StorEdge T3 Array Controller Card LEDs
TABLE 4-1
FC-AL Channel-Active LED Descriptions (Sun StorEdge T3 array)
Channel Active LED
(green)
Description
Off
Port disabled
Amber
Port enabled and not receiving signal from host
Green
Port enabled and idle
Blinking green
Port enabled and active
TABLE 4-2
Controller Status LED Descriptions (Sun StorEdge T3 array)
Controller Status LED
(green or amber)
Description
Off
Controller not installed (not recognized)
Green
Controller OK
Amber
Controller boot, shutdown, or firmware download in progress
Blinking amber
Controller failure; OK to replace controller
Note—Verify a controller card failure using the CLI or Sun StorEdge Component Manager.
FC-AL channel-active LED
Controller
status LED
Reset switch
Содержание StorEdge T3+
Страница 5: ...Regulatory Compliance Statements v ...
Страница 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...