Chapter 8
Diagnosing and Correcting FC-AL Loop Problems
8-5
8.2.1
The
fru stat
Command
The
fru stat
command returns the current condition of both disk ports (port 1
and port 2), as well as the status of the interconnect cards. If there are loop problems,
this might indicate certain disk ports have a status other than
ready,
or the loop
cards with a status other than
ready
or
enabled
.
CODE EXAMPLE 8-1
fru stat
Command Output
:/:<1> fru stat
CTLR STATUS STATE
ROLE
PARTNER TEMP
----- ----- ------- ------
------- ----
u1ctr ready enabled master
u2ctr
37.5
u2ctr ready enabled alt master u1ctr
39.5
DISK STATUS STATE
ROLE
PORT1 PORT2 TEMP VOLUME
---- ----- ------- --------- ----- ----- --- ------
u1d1 ready enabled data disk ready ready 35
v0
u1d2 ready enabled data disk ready ready 30
v0
u1d3 ready enabled data disk ready ready 30
v0
u1d4 ready enabled data disk ready ready 29
v0
u1d5 ready enabled data disk ready ready 35
v0
u1d6 ready enabled data disk ready ready 31
v0
u1d7 ready enabled data disk ready ready 35
v0
u1d8 ready enabled data disk ready ready 32
v0
u1d9 ready enabled data disk ready ready 37
v0
u2d1 ready enabled data disk ready ready 33
v1
u2d2 ready enabled data disk ready ready 33
v1
u2d3 ready enabled data disk ready ready 31
v1
u2d4 ready enabled data disk ready ready 31
v1
u2d5 ready enabled data disk ready ready 27
v1
u2d6 ready enabled data disk ready ready 32
v1
u2d7 ready enabled data disk ready ready 35
v1
u2d8 ready enabled data disk ready ready 30
v1
u2d9 ready enabled data disk ready ready 33
v1
LOOP STATUS STATE
MODE
CABLE1
CABLE2
TEMP
---- ------ ------- ------ ---------
--------
----
u2l1 ready
enabled master installed -
-
u2l2 ready
enabled slave
installed -
-
u1l1 ready
enabled master -
installed 37.5
u1l2 ready
enabled slave
-
installed 41.0
POWER STATUS STATE
SOURCE OUTPUT BATTERY TEMP
FAN1
FAN2
----- ------ ------- ------ ------ ------- ------ ------ ------
u1pcu1 ready enabled line
normal normal
normal normal normal
u1pcu2 ready enabled line
normal normal
normal normal normal
u2pcu1 ready enabled line
normal normal
normal normal normal
u2pcu2 ready enabled line
normal normal
normal normal normal
Содержание StorEdge T3+
Страница 5: ...Regulatory Compliance Statements v ...
Страница 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...