C-2
Sun StorEdge T3 and T3+ Array Field Service Manual • September 2001
C.1.1
Message Types
A syslog daemon exists in the hardware RAID controller that records system
messages and provides for remote monitoring. There are four possible levels of
messages, listed in
TABLE C-1
in order of severity.
C.1.2
FRU Identifiers
The syntax of the error message uses a FRU identifier to refer to a particular FRU in
a disk tray. This identifier contains a unit constant (u), the unit number (n), the FRU
constant (ctr for controller card, pcu for power and cooling unit, 1 for interconnect
card, d for disk drive), and the FRU number (n).
TABLE C-1
Message Types
Message Type
Definition
Error
Indicates a critical system event requiring immediate user
intervention or attention. For example, an over temperature
condition or a detected FRU being removed.
Warning
Indicates a possible event requiring eventual user intervention. For
example, a FRU being disabled and recovery procedure executed.
Notice
Indicates a system event that might be a side effect of other events
or may be a normal condition. For example, the power switch is
turned off.
Information
Indicates a system event that has no consequence on the running
health of the system. For example, a good state of a FRU.
TABLE C-2
FRU Identifers
FRU
Identifier
Unit Number
Controller card
unctr
n = unit number (1, 2, ...)
Power and cooling unit
unpcun
n = unit number (1, 2, ...)
n = pcu number (1, 2)
Interconnect card
unln
n = unit number (1, 2, ...)
n = interconnect number (1, 2)
Disk drive
undn
n = unit number (1, 2, ...)
n = disk drive number (1 to 9)
Содержание StorEdge T3+
Страница 5: ...Regulatory Compliance Statements v ...
Страница 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...