8-28
Sun StorEdge T3 and T3+ Array Field Service Manual • September 2001
14. Remove and replace the suspect disk drive from the enclosure.
See Section 5.3, “Repairing Disk Drives” on page 5-7.
The drive spins up and the
sysarea
data copies to it from another drive in the u1
enclosure. After the copy is complete, a volume reconstruction starts.
15. Stop the volume reconstruction operation.
Perform a
proc list
command to determine the process number of the volume
reconstruction. Use that process number with the
proc kill
command to stop the
reconstruction.
16. Rerun the
ofdg find
diagnostic through the suspect loop as described in Step 11
and Step 12.
Once the test completes, examine and compare the two outputs to insure that the
fault has been corrected.
a. If the problem is resolved, proceed with Step 18 through Step 17.
b. If the problem is not resolved, proceed with Step 18 through Step 17 and then
replace the backplane chassis.
See Section 8.4.4, “Chassis Replacement Procedure” on page 8-29 and Section 9.2,
“Replacing the Chassis/Backplane Assembly” on page 9-2”.
17. Remount the volumes.
18. Restart the volume reconstruction with the
vol recon
command on the replaced
disk drive.
:/:<12> proc list
VOLUME CMD_REF PERCENT TIME COMMAND
v0 8465 3 1:05 vol recon
:/:<13> proc kill 8465
:/:<14> vol mount v0
:/:<15> vol stat
v0 u1d1 u1d2 u1d3 u1d4 u1d5 u1d6 u1d7 u1d8 u1d9
mounted 0 0 0 0 0 0 0 0 0
v1 u2d1 u2d2 u2d3 u2d4 u2d5 u2d6 u2d7 u2d8 u2d9
mounted 0 0 0 0 0 0 0 0 0
:/:<16> vol recon u1d9
Содержание StorEdge T3+
Страница 5: ...Regulatory Compliance Statements v ...
Страница 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...