10-20
Sun StorEdge T3 and T3+ Array Field Service Manual • September 2001
If the array reports a ready status with functional FRUs, you can now restore the
data, if necessary, and return the array to operation as a single controller unit.
10.2.4.2
Alternate Master Unit to a Single Controller Unit
The former alternate master unit contains the same volume(s) as it did when
connected in the partner group. Those volumes are available when the unit is
powered on. However, the former alternate master unit might be operating on an
outdated file system. If you apply a firmware patch to the arrays while they were
connected in the partner group, the files contained on the array’s reserved system
area are not upgraded on the alternate master, but only on the master unit. When the
units are disconnected, the alternate master unit reverts to the file system stored on
its reserved system area.
To correct this situation and ensure that the array is ready for operation:
1. Install the latest firmware patch on the array.
This patch is available on the SunSolve web site:
http://sunsolve.sun.com
:/:<6> fru stat
CTLR STATUS STATE ROLE PARTNER TEMP
------ ------- ---------- ---------- ------- ----
u1ctr ready enabled master - 34.5
DISK STATUS STATE ROLE PORT1 PORT2 TEMP VOLUME
------ ------- ---------- ---------- --------- --------- ---- ------
u1d1 ready enabled data disk ready ready 33 v0
u1d2 ready enabled data disk ready ready 29 v0
u1d3 ready enabled data disk ready ready 30 v0
u1d4 ready enabled data disk ready ready 28 v0
u1d5 ready enabled data disk ready ready 28 v0
u1d6 ready enabled data disk ready ready 36 v0
u1d7 ready enabled data disk ready ready 27 v0
u1d8 ready enabled data disk ready ready 27 v0
u1d9 ready enabled data disk ready ready 34 v0
LOOP STATUS STATE MODE CABLE1 CABLE2 TEMP
------ ------- ---------- ------- --------- --------- ----
u1l1 ready enabled master - - 28.0
u1l2 ready enabled slave - - 31.0
POWER STATUS STATE SOURCE OUTPUT BATTERY TEMP FAN1 FAN2
------ ------- --------- ------ ------ ------- ------ ------ ------
u1pcu1 ready enabled line normal normal normal normal normal
u1pcu2 ready enabled line normal normal normal normal normal
Содержание StorEdge T3+
Страница 5: ...Regulatory Compliance Statements v ...
Страница 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Страница 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...