![Sun Microsystems StorEdge 3000 Series Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/sun-microsystems/storedge-3000-series/storedge-3000-series_installation-operation-and-service-manual_1392458064.webp)
4-10
Sun StorEdge 3000 Family Installation, Operation, and Service Manual • March 2004
See the chapter
for more information about your
array’s LEDs.
4.6
Reviewing and Changing SFP Ports
(Optional)
Each I/O controller module has six ports that accept SFP transceivers. These ports
are labeled FC0 through FC5. The default configurations do not include an SFP
connector on every SFP port. You might want to add or rearrange SFPs, depending
on the configuration mode (loop or point-to-point), number of planned host
connections, the necessary number of redundant connections to hosts, and the
number of expansion units needed.
The SFP is a single-port, optical SFP transceiver for multimode (short wave) or
single-mode (long wave) use. They are compatible with the Small Form Factor
Pluggable Multi-Sourcing Agreement (MSA, Sep. 2000), and 1x and 2x Fiber
Channel. The optical connector used is the low-profile LC connector.
SFPs are Sun field-replaceable units (FRUs) and can be ordered from Sun
Microsystems. These SFPs have been selected and tested to provide the necessary
reliability and performance. SFPs from other vendors are not supported.
To see an example of an array that has SFP connectors in all the SFP ports of the
RAID array and the upper expansion unit, refer to the illustration
Attached to Two Hosts and Two Expansion Units” on page 4-18
To review various configuration options, see the discussions following
“Configuration Overview” on page 5-7
. Refer also to the configuration options
presented in the
Sun StorEdge 3000 Family Best Practices
for the Sun StorEdge 3510 FC
Array.
4.6.1
Port Connectivity in a Dual-Controller Array
Drive channels connect to the internal drives in the array and can also connect to
drives in external expansion units. Configured for redundancy, each controller in a
dual-controller RAID array has two adjacent dedicated drive channels on one loop to
load-balance I/O operations (see
). Each drive channel has two SFP ports
that can be connected to expansion units. Drive channels 2 and 3 access all the disk
drives and are interconnected to load-balance I/O operations
.
Содержание StorEdge 3000 Series
Страница 14: ...xiv Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 18: ...xviii Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 38: ...1 12 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 48: ...2 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 54: ...3 6 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 140: ...5 62 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 180: ...7 32 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 208: ...8 28 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 242: ...B 28 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 247: ...Appendix D Record of Settings D 3 D 1 2 Logical Drive Partition Information LG Partition Size MB LG Partition Size MB ...
Страница 252: ...D 8 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...