1-4
Sun StorEdge 3000 Family Installation, Operation, and Service Manual • March 2004
Each RAID controller module can support up to 1 gigabyte of Sychronous Dynamic
Random Access Memory (SDRAM) with Error Control Check (ECC) memory. In
addition, each controller supports 64 megabytes (Mbyte) of on-board memory. Two
Application Specific Integrated Circuit (ASIC) controller chips handle the
interconnection between the controller bus, DRAM memory, and Peripheral
Component Interconnect (PCI) internal buses. They also handle the interface
between the on-board 2 Mbyte flash, 32 Kbyte nonvolatile random access memory
(NVRAM) RS-232 port chip, and 10/100 BASE-T Ethernet chip.
The RAID controller module is a multifunction board that provides six Small Form-
Factor Pluggable (SFP) ports, the SES logic, and the RAID controller. The SES logic
monitors various temperature thresholds, fan speed from each fan, voltage status
from each power supply, and the FRU ID.
Each RAID controller module incorporates SES direct-attached Fibre Channel
capability to monitor and maintain enclosure environmental information. The SES
controller chip monitors all in12 and +5 voltages, various temperature
sensors located throughout the chassis, each fan, and controls the front and back
panel LEDs and audible alarm. Both the RAID chassis and the expansion chassis
support dual SES failover capabilities for fully redundant event monitoring.
1.2.2
I/O Expansion Modules
The hot-serviceable I/O expansion modules also provide four SFP ports but do not
have battery modules or controllers, and are used only in expansion units.
1.2.3
Disk Drives
Each disk drive is mounted in its own sled assembly, known as an
air management
sled
. Each sled assembly has EMI shielding, an insertion and locking mechanism,
and a compression spring for maximum shock and vibration protection.
The drives can be ordered in 36-GB, 73-GB, and 146-GB sizes. Thirty-six-GB drives
have a rotation speed of 15,000 RPM, while 73-GB drives and 146-GB drives have a
rotation speed of 10,000 RPM. Each disk drive is slot-independent, meaning that
once a RAID set has been initialized, the system can be shut down and the drives
can be removed and replaced in any order. In addition, disk drives are field-
upgradeable to larger drives without interruption of service to user applications. The
drive firmware is also field-upgradeable, but the firmware upgrade procedure
requires interruption of service.
Содержание StorEdge 3000 Series
Страница 14: ...xiv Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 18: ...xviii Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 38: ...1 12 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 48: ...2 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 54: ...3 6 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 140: ...5 62 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 180: ...7 32 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 208: ...8 28 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 242: ...B 28 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 247: ...Appendix D Record of Settings D 3 D 1 2 Logical Drive Partition Information LG Partition Size MB LG Partition Size MB ...
Страница 252: ...D 8 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 270: ...G 12 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 280: ...H 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 312: ...K 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...