p
riNciple
The Stop & Go system comprises two operating modes:
automatic and manual.
a
utomatic
mode
- Press the yellow “auto” button
The yellow LED on indicates operation in automatic mode.
Once a job is started in the guidance bar, the boom section
control module will, where appropriate, send signals to
control the electric actuators.
When you have finished spreading the field, always
return to manual mode with the shutters closed,
then disconnect the Stop & Go control unit.
Moreover, you are also advised to switch off the
guidance bar.
Please consult your guidance bar manual in the
event that the GPS signal is lost.
Depending on the brand, the guidance bar will
close the fertiliser spreader shutters (safety), or
leave them in the position in which they were before
the GPS signal was lost.
If in doubt, the Stop & Go control unit allows you
to work in manual mode. This is strongly recom-
mended.
The guidance bars are not generally able to monitor
the tractor in reverse. You should therefore never
attempt to do this, in order to avoid incorrect
spreading in the area of the plot concerned.
The user can comfortably
spread fertiliser over the
entire plot without needing
to switch to manual mode.
(Info-Traçabilité) Modification sulky 00 vers 01
Directives pour TRADUCTION SE
À AJOUTER ou À TRADUIRE
À SUPPRIMER
À VÉRIFIER
(Info-Traçabilité) Modification sulky 00 vers 01
Directives pour TRADUCTION SE
À AJOUTER ou À TRADUIRE
À SUPPRIMER
À VÉRIFIER
L’utilisateur peut aisément
épandre sur la totalité de
sa parcelle sans avoir à
repasser en mode manuel.
66
67
GB
SE
Programming / Programmering
Programming / Programmering
2
G
G
G