April 13, 2009
115-V 20-Amp 60-Hz Self-Timed Unit
26
BOTTOM VIEW OF DRIVE UNIT
DRIVE UNIT ASSEMBLY (1) EC23
THIS SHOCK BUMPER RING IN POSITION.
SPACER. IT IS REQUIRED TO KEEP
NOTE LOCATION OF ALUMINUM
CASE ASSEMBLY (1) EC12
FRONT FACE
AND (3) LOCK WASHERS (AEC1238)
CONSISTING OF (3) NUTS (AEC1224)
DRIVE UNIT ASSEMBLY MOUNTING
DRIVE UNIT
REMOVAL OF
SHOCK MOUNT
SUITMATE
®
UNIT
BOTTOM VIEW OF
L1
L2
Black Wire terminated with Insulated
Connector. Secured to this terminal (L1).
Green Wire secured to Motor Frame
with Green (Hex Head) Screw
This switch must be in the
115 position.
(2) White Wires - one terminated with
Insulated Connector, second with Ring
Terminal to terminal (L2).
Photograph shows the Correct Position of Wires for Rewiring the Motor
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115